نتایج جستجو برای: tof pet

تعداد نتایج: 65497  

ژورنال: طب جنوب 2022
Ay , Mohammad Reza, Ghafarian , Pardis, Gharepapagh , Esmaeil, Rezaei , Sahar, Sarkar , Saeid,

Background: The present study aims to assess the impact of various image reconstruction methods in 18F-FDG PET/CT imaging on the quantification performance of the proposed technique for joint compensation of respiratory motion and partial volume effects (PVEs) in patients with non-small cell lung cancer. Materials and Methods: An image-based deconvolution technique was proposed, incorporating w...

2015
Sune Folke Pedersen Benjamin Vikjær Sandholt Sune Høgild Keller Adam Espe Hansen Andreas Ettrup Clemmensen Henrik Sillesen Liselotte Højgaard Rasmus Sejersten Ripa Andreas Kjær

All patients referred to our institution for carotid endarterectomy were screened for inclusion. Inclusion criteria were significant carotid stenosis with recent cerebrovascular symptoms; stroke, amaurosis fugax or TIA. Exclusion criteria were age <50 years, current infection, pregnancy, renal insufficiency, or severe claustrophobia. All patients underwent two simultaneous PET/MR procedures aft...

2013
David Watts Giacomo Borghi Fabio Sauli Ugo Amaldi

On-line verification of the delivered dose during proton and carbon ion radiotherapy is currently a very desirable goal for quality assurance of hadron therapy treatment plans. In-beam positron emission tomography (ibPET), which can provide an image of the β+ activity induced in the patient during irradiation, which in turn is correlated to the range of the ion beam, is one of the modalities fo...

Journal: :Bio-Algorithms and Med-Systems 2014
Michal Silarski Eryk Czerwinski Tomasz Bednarski Pawel Moskal Piotr Bialas Lukasz Kaplon Andrzej Kochanowski Grzegorz Korcyl Jakub Kowal Pawel Kowalski Tomasz Kozik Wojciech Krzemien Marcin Molenda Szymon Niedzwiecki Marek Palka Monika Pawlik-Niedzwiecka Lech Raczynski Zbigniew Rudy Piotr Salabura Neha Gupta-Sharma Artur Slomski Jerzy Smyrski Adam Strzelecki Wojciech Wislicki Marcin Zielinski Natalia Zon

All of the present methods for calibration and monitoring of time-of-flight positron emission tomography (TOF-PET) scanner detectors utilize radioactive isotopes, such as 22Na or 68Ge, which are placed or rotate inside the scanner. In this article, we describe a novel method based on the cosmic rays application to the PET calibration and monitoring methods. The concept allows to overcome many o...

2009
W. W. Moses

PET scanners based on LSO have the potential for significantly better coincidence timing resolution than the 6 ns FWHM typically achieved with BGO. This study analyzes the performance enhancements made possible by improved timing as a function of the coincidence time resolution. If 500 ps FWHM coincidence timing resolution can be achieved in a complete PET camera, the following four benefits ca...

Journal: :Annals of nuclear medicine 2015
Takafumi Taniguchi Go Akamatsu Yukiko Kasahara Katsuhiko Mitsumoto Shingo Baba Yuji Tsutsui Kazuhiko Himuro Shohei Mikasa Daisuke Kidera Masayuki Sasaki

OBJECTIVE The aim of this study was to evaluate the effect of the point spread function (PSF) and time of flight (TOF) on PET/CT images of overweight patients in relation to the iteration number and the acquisition time. METHODS This study consisted of a phantom study and a clinical study. The NEMA IEC body phantom and a 40 cm diameter large phantom (LG phantom) simulating an overweight patie...

2014
Alexander S. Pasciak Austin C. Bourgeois J. Mark McKinney Ted T. Chang Dustin R. Osborne Shelley N. Acuff Yong C. Bradley

Before the advent of tomographic imaging, it was postulated that decay of (90) Y to the 0(+) excited state of (90)Zr may result in emission of a positron-electron pair. While the branching ratio for pair-production is small (~32 × 10(-6)), PET has been successfully used to image (90) Y in numerous recent patients and phantom studies. (90) Y PET imaging has been performed on a variety of PET/CT ...

Journal: :Journal of nuclear medicine : official publication, Society of Nuclear Medicine 2012
Go Akamatsu Kaori Ishikawa Katsuhiko Mitsumoto Takafumi Taniguchi Nobuyoshi Ohya Shingo Baba Koichiro Abe Masayuki Sasaki

UNLABELLED The aim of this study was to investigate the effects of the point-spread function (PSF) and time-of-flight (TOF) on improving (18)F-FDG PET/CT images in relation to reconstruction parameters and noise-equivalent counts (NEC). METHODS This study consisted of a phantom study and a retrospective analysis of 39 consecutive patients who underwent clinical (18)F-FDG PET/CT. The body phan...

Journal: :Bio-Algorithms and Med-Systems 2014
Wojciech Krzemien Michal Silarski Karol Stola Damian Trybek Tomasz Bednarski Piotr Bialas Eryk Czerwinski Lukasz Kaplon Andrzej Kochanowski Grzegorz Korcyl Jakub Kowal Pawel Kowalski Tomasz Kozik Marcin Molenda Pawel Moskal Szymon Niedzwiecki Marek Palka Monika Pawlik-Niedzwiecka Lech Raczynski Zbigniew Rudy Piotr Salabura Neha Gupta-Sharma Artur Slomski Jerzy Smyrski Adam Strzelecki Wojciech Wislicki Marcin Zielinski Natalia Zon

Novel time-of-flight positron emission tomography (TOF-PET) scanner solutions demand, apart from the state-of-the-art detectors, software for fast processing of the gathered data, monitoring of the whole scanner, and reconstruction of the PET image. In this article, we present an analysis framework for the novel STRIP-PET scanner developed by the J-PET collaboration in the Institute of Physics ...

Journal: :Physics in medicine and biology 2015
Abolfazl Mehranian Habib Zaidi

In standard segmentation-based MRI-guided attenuation correction (MRAC) of PET data on hybrid PET/MRI systems, the inter/intra-patient variability of linear attenuation coefficients (LACs) is ignored owing to the assignment of a constant LAC to each tissue class. This can lead to PET quantification errors, especially in the lung regions. In this work, we aim to derive continuous and patient-spe...

نمودار تعداد نتایج جستجو در هر سال

با کلیک روی نمودار نتایج را به سال انتشار فیلتر کنید