نتایج جستجو برای: total harmonic distortion
تعداد نتایج: 881662 فیلتر نتایج به سال:
This paper presents the design of a sub-threshold CMOS G,„-C low-pass filter in a portable ECG detection system. The proposed filter is formed by cascading 6 stages of identical l^'-order low-pass sections. With a minimum number of active components in the l^'-order section, the noise contribution of the circuit can be kept low while minimizing the size of transistors and capacitors. The filter...
In order to reduce the total harmonic distortion (THD) of a bandpass-based oscillator, instead of using a conventional hard limiter, a multilevel hard limiter (MHL) is proposed which inherently removes the third and the fifth-order harmonics from the frequency spectrum of its output signal. The input–output characteristic of the proposed MHL contains slope values of only zero and infinity, maki...
This paper presents a new three-phase five-level inverter for direct torque control (DTC) drives application. The advantages of the inverter are reduced output harmonics, switching losses and number of power switches. The multilevel PWM modulation method as well as output voltage analysis based on symmetrical sampling are presented. The proposed inverter is compared with the conventional invert...
DC underground traction systems are a powerful source of harmonic distortion, and so, suitable corrective actions have to be taken. For the design of these corrective actions simulation has proved to be a very useful tool. In this paper, the simulation of an active filter for the reduction of the current harmonic distortion of an underground traction system is presented.
In this paper presents a fast new PI controlled DSTATCOM used to compensate for harmonic distortion in threephase system. The DSTATCOM employs a simple Method for the calculation of the reference compensation current based. The presented DSTATCOM is able to operate in balanced, unbalanced and Variable load conditions. Classic filters may not have satisfactory performance in fast varying conditi...
Power quality standards (IEEE-519) require to limit the total harmonic distortion within satisfactory range caused by power electronic based devices. Our work deals with the design of hybrid active filter to reduce current perturbations produced by power electronics based devices. The Instantaneous Active and Reactive Power Method (pq) is used to perform the identification of disturbing current...
This paper presents an algorithm for estimating the Total Harmonic Distortion (THD) in the electrical power grid nodes, which is based on a load flow analysis by frequency component. The aim of this algorithm is, on the one hand, to model the linear and non-linear loads which would be part of an electrical network and, on the other hand, to estimate the THD which would appear in the network nod...
Milan Srndovic 1,*, Yakov L. Familiant 2, Gabriele Grandi 1 and Alex Ruderman 2 1 Department of Electrical, Electronic, and Information Engineering, University of Bologna, Viale Risorgimento 2, Bologna 40136, Italy; [email protected] 2 Power Electronics Research Lab, Nazarbayev University, Kabanbay Batyr Avenue 57, Astana 010000, Kazakhstan; [email protected] (Y.L.F.); alexander....
The special generator of testing signal was designed for the frequency of 441.171 kHz. The generator consists of the special crystal oscillator and a high power amplifier. The frequency stability of the generator is in order of 10/day, the output power 1W, the value of SINAD is close to 120 dB and the total harmonic distortion under 170 dB by using of linear narrow-band filter.
Three different conventional control strategies for extracting reference currents for shunt active power filters have been evaluated and their performance has been compared under various non linear loads. Comparison of the compensation ability of different control strategies based on THD and speed will be done and suggestions will be given for the selection of strategy to be used under differen...
نمودار تعداد نتایج جستجو در هر سال
با کلیک روی نمودار نتایج را به سال انتشار فیلتر کنید