Journal: :Brazilian journal of otorhinolaryngology 2006
Bernardo Cunha Araujo Filho Flavio A Sakae Luiz Ubirajara Sennes Rui Imamura Marcus R de Menezes

AIMS The objective of the present study was to determine the specificity, sensitivity and accuracy of intraoral and transcutaneous ultrasound (US) in the diagnosis of peritonsillar cellulitis and abscess. STUDY DESIGN Clinical-Prospective. MATERIAL AND METHODS Thirty nine patients were seen at the otorhinolaryngology emergency department of the University Hospital, of the School of Medicine...

Journal: :Biomedical papers of the Medical Faculty of the University Palacky, Olomouc, Czechoslovakia 2007
Lucia Stillova Katarina Matasova Tatiana Mikitova Juraj Stilla Hana Kolarovszka Mirko Zibolen

AIMS The aim of this prospective study was to evaluate the accuracy of transcutaneous bilirubinometry using the Minolta Air-Shields JM-103 device in preterm newborns of gestational age 32-34 weeks, and to identify the most appropriate measurement site. METHODS Transcutaneous bilirubin (TcB) measurements were performed over forehead, sternum and abdomen, if total serum bilirubin (TSB) had to b...

Journal: :Nephrology, dialysis, transplantation : official publication of the European Dialysis and Transplant Association - European Renal Association 2009
Daniel Schock-Kusch Maliha Sadick Nadja Henninger Bettina Kraenzlin Guenter Claus Hans-Martin Kloetzer Christel Weiss Johannes Pill Norbert Gretz

BACKGROUND Inulin/sinistrin (I/S) clearance is a gold standard for an accurate assessment of glomerular filtration rate (GFR). Here we describe and validate an approach for a transcutaneous determination of GFR by using fluorescein-isothiocyanate-labelled sinistrin (FITC-S) in rats. METHODS Using a small animal imager, fluorescence is measured over the depilated ear of a rat after the injecti...

Journal: :Journal of rehabilitation medicine 2009
Tiebin Yan Christina W Y Hui-Chan

OBJECTIVE To investigate whether transcutaneous electrical stimulation, when applied to acupuncture points in patients after acute stroke, decreases spasticity and/or increases muscle strength more effectively than placebo stimulation and standard rehabilitation. DESIGN Randomized control trial. SUBJECTS Sixty-two patients aged 70.0 (standard deviation 7.4) years and 9.2 (standard deviation...

Journal: :Journal of emerging diseases and virology 2021

Objective: Evaluate the safety and efficacy of transcutaneous vagus nerve stimulation in preventing respiratory failure improving survival hospitalized COVID-19 patients.

Journal: :IEICE Transactions 2005
YoungHo Yoon Eui-Sung Jung Byung-Seop Song Sang-Heun Lee Jin-Ho Cho

An infrared (IR) transcutaneous remote control was designed for use in the totally implantable middle ear system. Considering the IR reflection, absorption and scattering effect of the skin, the required IR radiant intensity is calculated. After we have implemented the designed control, the transcutaneous operation experiment was carried out using a porcine skin. key words: implantable middle e...

Journal: :Otology & neurotology : official publication of the American Otological Society, American Neurotology Society [and] European Academy of Otology and Neurotology 2013
Françoise Denoyelle Nicolas Leboulanger Cyrille Coudert Olivia Mazzaschi Natalie Loundon Eric Vicaut Natacha Tessier Eréa-Noël Garabedian

OBJECTIVE To report preliminary results of a new closed-skin, transcutaneous bone conduction device (BCD) in 6 children with high-grade ear atresia. SETTINGS Tertiary care center; prospective study; we evaluated the gain with masking of the contralateral ear and the benefit of hearing rehabilitation with the transcutaneous BCD in noise: speech-in-noise tests, conducted in real life condition ...

2003
David J. Cassidy Thomas Zullo

The objective of this study was to assess the changes in transcutaneous oxygen tension in pediatric patients undergoing nitrous oxide-oxygen analgesia. A total of 19 healthy patients, ranging in age from 3 to 19 years with a mean age of 9.8 years, were included. Transcutaneous oxygen monitoring was performed; following stabilization, baseline readings were obtained. Oxygen was delivered at 3 I/...

2015
Sabine Reinfeldt Bo Håkansson Hamidreza Taghavi Måns Eeg-Olofsson

The different kinds of bone-conduction devices (BCDs) available for hearing rehabilitation are growing. In this paper, all BCDs currently available or in clinical trials will be described in categories according to their principles. BCDs that vibrate the bone via the skin are referred to as skin-drive devices, and are divided into conventional devices, which are attached with softbands, for exa...

Journal: :British heart journal 1989
C Mannheimer H Emanuelsson F Waagstein C Wilhelmsson

The influence of naloxone on the effects of high frequency transcutaneous electrical nerve stimulation in angina pectoris induced by atrial pacing was studied in 11 patients with severe coronary artery disease. The patients were catheterised and treated with transcutaneous electrical nerve stimulation on two occasions, double blind and in random order, with a single intravenous dose of saline o...