نتایج جستجو برای: transformer testing

تعداد نتایج: 348382  

2004
John A. Katsigiannis Pavlos S. Georgilakis Athanasios T. Souflaris Kimon P. Valavanis

Transformer fault diagnosis and repair is a complex task that includes many possible types of faults and demands special trained personnel. In this paper, Petri Nets are used for the simulation of transformer fault diagnosis process and the definition of the actions followed to repair the transformer. An integrated safety detector relay is used for transformer fault detection. Simulation result...

2011
Rawid Banchuin

According to the chronological literature survey, there exist three types of the on-chip transformer i.e the traditional on-chip passive transformer, the Distributed active transformer (DAT), and the CMOS gyrator-C active transformer (Yuan 2007). Formerly, there exist many review articles on the on-chip transformer. However, these articles focus on the on-chip passive transformer due to its ren...

2016
I. Fofana Y. Bouslimi H. Hemmatjou C. Volat K. Tahiri

The paper presents the research results on electrostatic charging tendency (ECT) of transformer oil in a spinning disk system. The measurements were performed at different aging severity. Changes in static electrificationwere related to some classical aging indexes (conductivity, dissipation factor, water content, resistivity, etc.). Fast, inexpensive and reliable laboratory testing procedures ...

2015
Liu Tong

Transformer is the power equipment of power system core. Intelligent monitoring and operation of transformer can not only monitor the full range of the transformer, the realization of state evaluation, it should be required repair, maintenance required good, but also on the latent fault early diagnosis and prediction. Research on transformer intelligent monitoring and operating technology of sa...

2012
Tomohiro Yamanaka Yasuyoshi Kaneko Shigeru Abe Tomio Yasuda

A contactless power transfer system for charging electric vehicles requires a high efficiency, a large air gap, and a good tolerance to lateral misalignment and needs to be compact and lightweight. A double-sided winding 10 kW transformer based on a 1.5 kW H-shaped core transformer was developed for a rapid charger. Even though the transformer capacity was increased, the dimensions of the 10 kW...

2009
J. G. Lawton A. G. Barrett R. R. Moats D. L. Eckhardt R. J. Renfrow

To facilitate the construction of the high-power magnetron, the entire output section, including the quarter wave transformer and window, has been redesigned. The new design is based on standard S band waveguide. The quarter wave transformer was changed to increase the external loading of the tube. Cold test measurements on a tube with the redesigned output section give an external Q of 230. Wo...

Transformer oil is one of the most important materials which are used in electrical and transformer industrial. The main function is protection and insulation of transformer core components, as well as heat transfer from its core to environment. Improving the performance of this material has been one of the researchers' concerns. The effect of different nanoparticle on the electrical breakdown ...

2016
Caijun Xu Liping Zhang Yuchen Chen Zhifeng Liu

in working process of power transformer, which directly affects the safe operation of transformer oil temperature as well as the stability of the network, so vital to transformer oil temperature detection and control. Based on single chip and chip design of digital temperature measurement transformer oil temperature of an intelligent control system. The system uses a digital temperature sensor ...

In this paper, a new model based on the thevenin equivalent circuit for investigating the ultra-saturation phenomenon during the energization of a loaded power transformer is presented and its effect on the differential protection of the transformer is considered. The ultra-saturation phenomenon causes the mal-operation of the power transformer differential protection. So, the description a...

2005
Pat Bodger

An overview of the research and developments into new transformer design, undertaken in the Department of Electrical and Computer Engineering, University of Canterbury, is presented. Initially, single phase, 50 Hz, l1/0.23kV pole mount distribution transformers were fitted with either silicon or amorphous steel cores. The transformer tanks were filled with either standard transformer oil or liq...

نمودار تعداد نتایج جستجو در هر سال

با کلیک روی نمودار نتایج را به سال انتشار فیلتر کنید