نتایج جستجو برای: virtual wedge
تعداد نتایج: 158550 فیلتر نتایج به سال:
background: physical wedges are still widely used as beam modifiers in external beam radiotherapy. however the presence of them in the beam trace may cause beam hardening which may not be considered in many treatment planning systems. the aim of this study is to investigate the beam hardening effect generated by physical wedges via different beam quality indexes as photon spectrum, half value l...
0
BACKGROUND Theoretical considerations suggest that leg length increases after opening wedge high tibial osteotomy (HTO) and decreases after closing wedge HTO; however, in vivo studies have yielded conflicting results. This meta-analysis therefore assessed changes in leg length after opening wedge and closing wedge HTO. METHODS All studies comparing pre- and postoperative leg length in patient...
background: one of the main causes of induction of secondary cancer in radiation therapy is neutron contamination received by patients during treatment. objective: in the present study the impact of wedge and block on neutron contamination production is investigated. the evaluations are conducted for a 15 mv siemens primus linear accelerator. methods: simulations were performed using mcnpx mon...
Background: The presence of a wedge filter in the beam trajectory can modify the beam quality and cause some changes in the dosimetry parameters which are usually difficult to be measured directly and accurately. Material and Methods: In this study the MCNP-4C Monte Carlo code was used to simulate the 9 MV photon beam generated by a linear accelerator. Upon getting a good agreement bet...
Physically correct rendering of environment illumination has been a long-standing challenge in interactive graphics, since Monte-Carlo ray-tracing requires thousands of rays per pixel. We propose accurate filtering of a noisy Monte-Carlo image using Fourier analysis. Our novel analysis extends previous works by showing that the shape of illumination spectra is not always a line or wedge, as in ...
background: considering suggested formula in the references and pcwp measured by catheterism, in the present study the relation between pulmonary capillary wedge pressure (pcwp) measured the flow velocity of mitral valve and mitral annulus motion through tissue doppler imaging is evaluated methods: 52 cases of severe ms were admitted for balloon mitral valvolotomy (bmv) are included in this stu...
in this research, numerical simulation of a symmetric impact of a 2-d wedge, considering dynamic equations in two-phase flow is taken into account. the two-phase flow around the wedge is solved based on finite volume method and volume of fluid (vof) scheme. the dynamic mesh model is used to simulate dynamic motion of the wedge, thereby the effects of different dynamic meshes in both structured ...
High tibial osteotomy (HTO) has been widely used for clinical treatment of osteoarthritis of the medial compartment of the knee, and both opening-wedge and closing-wedge HTO are the most commonly used methods. However, it remains unclear which technique has better clinical and radiological outcomes in practice. To systematically evaluate this issue, we conducted a comprehensive meta-analysis by...
Background: One of the main causes of induction of secondary cancer in radiation therapy is neutron contamination received by patients during treatment.Objective: In the present study the impact of wedge and block on neutron contamination production is investigated. The evaluations are conducted for a 15 MV Siemens Primus linear accelerator. Methods: Simulations were performed using MCNPX Monte...
نمودار تعداد نتایج جستجو در هر سال
با کلیک روی نمودار نتایج را به سال انتشار فیلتر کنید