In this paper, a new control strategy is proposed for implementation in low-voltage microgrids with balanced/ unbalanced load circumstances. The proposed scheme contains, the power droop controllers, inner voltage and current loops, the virtual impedance loop, the voltage imbalance compensation. The proposed strategy balances the voltage of the single-phase critical loads by compensating the im...
In this paper, the performance of two types of FACTS devices in order to enhance the power system static voltage stability has been investigated. These devices include Static Var Compensator (SVC) and Thyristor Controlled Series Capacitor (TCSC). The modeling of the Single Machine Infinite Bus (SMIB) and aforesaid devices has been made up in steady state mode with disregarding of the generator ...
In methods presented to calculate the voltage collapse point, the transmission system is usually the only part of the power system that is completely modeled. Distribution systems are often replaced by aggregate load models because the use of the detailed model of distribution systems in voltage stability analysis not only increases the computation time, but also decreases the probability of co...
Distributed generation (DG) sources are becoming more prominent in distribution systems due to the incremental demands for electrical energy. Locations and capacities of DG sources have great impacts on the system losses in a distribution network. This paper presents a study aimed for optimally determining the size and location of distributed generation units in distribution systems with differ...
Load sensor is developed using mamdani type fuzzy model. It is two input one output model. Inputs taken for the load sensor are load and displacement and voltage is taken as output. The model is simulated using MATLAB Fuzzy Logic Toolbox and simulation results are shown in this paper. Index Terms —Fiber Bragg Grating sensor, Fuzzy logic, Load sensor, Mamdani, Windmill blades.
This paper proposes a new voltage stability assessment method based on vector analysis method. This index extraction process relies on measurements of active and reactive powers from connected buses to the generator buses. Therefore, a limit for beginning of voltage collapse is determined based on the maximum power transfer theory. On the other hand, when the system requires load shedding, a ne...
Distributed generation (DG) sources are becoming more prominent in distribution systems due to the incremental demands for electrical energy. Locations and capacities of DG sources have great impacts on the system losses in a distribution network. This paper presents a study aimed for optimally determining the size and location of distributed generation units in distribution systems with differ...
This paper presents the no-load practical synchronous speed characteristics of a laboratory model induction machine of 120 W capacity. Critical, minimum and maximum capacitance required for excitation are calculated from the no load curve for voltage buildup, rated voltage and current respectively; at various super synchronous speeds. A realistic model of the machine is presented on Matlab/Simu...
Economic and environmental concerns will slow down the expansion of the transmission system in many countries. The addition of new transmission lines will be few and far between. The deregulation of the power supply will introduce new power flow patterns on the bulk transmission systems. The net result is that the power systems will operate much closer to their transfer limits and operate there...