نتایج جستجو برای: wear testing

تعداد نتایج: 362427  

2016
Benjamin J. Hunt James E. Krzanowski

The wear properties of biomaterials have been demonstrated to have a high importance within orthopedic bearing surfaces. This study performed a comparison of the wear between the two main grades of Ultra High Molecular Weight Polyethylene types GUR 1020 and GUR 1050 articulating against Cobalt Chromium. Such a high capacity wear comparison has not been reported elsewhere in the scientific liter...

2011
Strickland Browne

Introduction: Experimental wear testing is well-established as an important part of the TKR design process. Recently, in-silico models have proved their value to corroborate long-term in-vitro results on a much shorter timescale [1]. Both FE-based models & multi-body dynamics can be used to predict contact pressures, sliding distances and cross-shear (CS). The precise mechanisms of wear are not...

2002

Aseptic loosening attributed to wear debris mediated osteolyses is the major concern in hip arthroplasty. Modern highly cross linked polyethylene reduces wear by > 90% in vitro, seemingly without major disadvantages. It has however not yet been subjected to extensive in clinical testing with high accuracy methods. Since the in vivo wear situation is complex and lab results earlier have made inc...

2015
A. Shebani C. Pislaru

Abstract—The wear measuring and wear modelling are fundamental issues in the industrial field, mainly correlated to the economy and safety. Therefore, there is a need to study the wear measurements and wear estimation. Pin-on-disc test is the most common test which is used to study the wear behaviour. In this paper, the pin-on-disc (AEROTECH UNIDEX 11) is used for the investigation of the effec...

Journal: :Proceedings of the Institution of Mechanical Engineers. Part H, Journal of engineering in medicine 2004
R Bader E Steinhauser U Holzwarth M Schmitt W Mittelmeier

After total hip replacement, some cemented titanium stems show above-average early loosening rates. Increased release of wear particles and resulting reaction of the peri-prosthetic tissue were considered responsible. The objective was to develop a test method for analysing the abrasive wear behaviour of cemented stems and for generating wear particles at the interface with the bone cement. By ...

2014
Steven M Kurtz Daniel W MacDonald Sevi Kocagöz Mariya Tohfafarosh Doruk Baykal

The objective of this study was to assess the suitability of using multidirectional pin-on-disk (POD) testing to characterize wear behavior of retrieved ultrahigh molecular weight polyethylene (UHMWPE). The POD wear behavior of 25 UHMWPE components, retrieved after 10 years in vivo, was compared with 25 that were shelf aged for 10-15 years in their original packaging. Components were gamma ster...

2006
Matthew Hannen

Over the past three decades more than a half a million joint replacements have been performed. Several advances have been made to the design of the implants, but despite the large success of these procedures, loosening of the components and periprosthetic osteolysys often requires a revision surgery. In looking at what causes this, the wear of the UHMWPE articulation surface and the associated ...

Journal: :Yonsei medical journal 2004
Kwon-Yong Lee Shin-Yoon Kim Daehwan Shin Sungjae Lee Sukyoung Kim

After the gamma-irradiation sterilization, the most widely used orthopaedic grade polymer bearing liner material for the total joint replacement, ultra-high molecular weight polyethylene (UHMWPE), degrades through the progressive in vivo oxidation. The oxidative degradation makes UHMWPE brittle and leads to reduction of its mechanical properties. In this study, the effect of the in vivo post-ir...

2013
Prashant Shrivastava

In this work the effects of WC concentration on abrasive wear behavior by thermally sprayed WC coating was evaluated using three body abrasive wear tester. A different combination of WC and NI coatings were deposited on steel substrates by flame spraying using powder with different WC concentrations (0 %, 12.5 %, 25 %, and 50 %). Flame torch was used for heating and coating of process. Microstr...

M. Salehi and F. Ashrafizadeh, M. Shamanian,

The use of Fe-Al intermetallic compound coatings has been investigated in order to improve the tribological behaviour of carbon tool steel. The coatings were formed by a pack cementation process and subsequently diffusion annealing at 900˚C in an argon controlled atmosphere. The optimum diffusion time was selected on the basis of optimum thickness and tribological behaviour. The microstructure...

نمودار تعداد نتایج جستجو در هر سال

با کلیک روی نمودار نتایج را به سال انتشار فیلتر کنید