نتایج جستجو برای: a sample ti
تعداد نتایج: 13474203 فیلتر نتایج به سال:
background: titanium (ti) implants are commonly coated with hydroxyapatite (ha). however, ha has some disadvantages such as brittleness, low tensile strength and fracture toughness. it is desirable to combine the excellent mechanical properties of zro2 and the chemical inertness of al2o3 with respect to the purpose of this project which was coating ti implants with ha-zro2-al2o3 to modify the s...
Introduction: SiC is the best-studied type of presolar grains [1]. Thousands of individual grains have been measured for their C and Si isotopic compositions [2-4] and many of these have been measured for additional isotopic systems, as well. Despite this wealth of data and the fact that Ti is one of the most abundant trace elements in SiC, only approximately 110 SiC grains have had their Ti is...
In this study, corrosion behavior of Ti-6Al-4V titanium alloy joint by friction stir welding with a rotational speed of 375 rpm and a travel speed of 100 mm/min was investigated. The welding procedure was carried out under β-transus temperature that was consisted of equiaxed grains in the stir zone. The corrosion behavior of the welded joint was investigated in 3.5% NaCl solution at temperature...
In this study, corrosion behavior of Ti-6Al-4V titanium alloy joint by friction stir welding with a rotational speed of 375 rpm and a travel speed of 100 mm/min was investigated. The welding procedure was carried out under β-transus temperature that was consisted of equiaxed grains in the stir zone. The corrosion behavior of the welded joint was investigated in 3.5% NaCl solution at temperature...
A method for the determination of Ti and V using inductively coupled plasma atomic emission spectrometry (ICP OES) in Ziegler-Natta polymerization catalysts is proposed. The concentrations of both Ti and V are efficiently determined after catalyst acid digestion with a mixture of HNO3 + HCl + HF and heating (160 degrees C for 6 h) or with 10% (v/v) H2SO4 and heating (160 degrees C for 6 h) or w...
آلکواکسیدهای al(och(ch3)2)3، ti(och2ch3)4، ti(och(ch3)2)4 و nb(och2ch3)5 با لیگاند کی لیت ساز پیریدین-2-کربالدهید اکسیم پایدار شده و با طیف سنجی های 1h, 13c, 27al, 93nb nmr مورد بررسی قرار گرفتند و ساختارهایی برای آنها پیشنهاد گردید. ساختار ترکیب (3)، [ti2o(och(ch3)2)4(oncc5h5n)2] به وسیله پراش پرتو ایکس از تک بلور تعیین شد. ترکیب (3) در شبکه مونو کلینیک با گروه فضایی p21/n و z=4 و ابعاد a=11.3...
AIM The aim of this study was to firstly evaluate the esthetics of a dielectric multilayer coating on titanium below porcine tissue (in vitro porcine model). Secondly, a polymer model was used to investigate the same samples to compare the models to each other and discuss their validity for optical assessment of esthetic coatings for implant applications. MATERIALS & METHODS A dielectric mirr...
AUTHOR EMAIL ADDRESS ([email protected]) RECEIVED DATE (to be automatically inserted after your manuscript is accepted if required according to the journal that you are submitting your paper to) TITLE RUNNING HEAD 'High temperature stable anatase TiO 2 ' CORRESPONDING AUTHOR FOOTNOTE *[email protected] 2 ABSTRACT: In the absence of a dopant or precursor modification, anatase to rutile tra...
A co-precipitation method was used for synthesis of pure MgTiO3 ceramic powder with Mg(NO3)2.6H2O, TiCl4 or C12H28O4Ti and NaOH as raw materials. In this method, solutions of 1 M, Mg (NO3)2 6H2O and 2 M, NaOH were prepared. A stoichiometric amount of Ti precursors from TiCl4 or C12H28O4Ti was weighted. Solutions of Mg (NO3)2. 6H2O and Ti precursor were added dropwise to NaOH solution unde...
Microbiologically induced corrosion (MIC) of metallic devices/implants in the oral region is one major cause of implant failure and metal allergy in patients. Therefore, it is crucial to develop practical approaches which can effectively prevent MIC for broad clinical applications of these materials. In the present work, tantalum nitride (TaN)-decorated titanium with promoted bio-corrosion and ...
نمودار تعداد نتایج جستجو در هر سال
با کلیک روی نمودار نتایج را به سال انتشار فیلتر کنید