2003
P. Y. Lin P. N. Roschke C. H. Loh C. P. Cheng

A series of large-scale experimental tests is conducted on a mass equipped with a hybrid controlled base-isolation system that consists of rolling pendulum system (RPS) and a 20 kN magnetorheological (MR) damper. The 12-ton mass and its hybrid isolation system are subjected to various intensities of nearand far-fault earthquakes on a large shake table. Fuzzy controllers use feedback from displa...

Journal: :Seismic Isolation and Protective Systems 2010

F. Ahmed G. M., S. A. Khan

This article reports the active control of base flows using the experimental procedure. Active control of base pressure helps in reducing the base drag in aerodynamic devices having suddenly expanded flows. Active control in the form of microjets having 0.5 mm radius placed at forty-five degrees apart is employed to control the base pressure. The Mach numbers of the present analysis are 1.7, 2....

Journal: :civil engineering infrastructures journal 0
shaghayegh alvandi m.sc., student, school of civil engineering, college of engineering, university of tehran, p.o. box: 11155-4563, tehran, iran. mehdi ghassemieh associate professor, school of civil engineering, college of engineering, university of tehran, p.o. box: 11155-4563, tehran, iran.

in the last two decades, there has been an increasing interest in structural engineering control methods. shape memory alloys and seismic isolation systems are examples of passive control systems that use of any one alone, effectively improve the seismic performance of the structure. characteristics such as large strain range without any residual deformation, high damping capacity, excellent re...

Ali Tayaran Mahmood Hosseini

In this paper a new isolating system is introduced for short to mid-rise buildings. In comparison to conventional systems such as LRB and HRB, the proposed system has the advantage of no need to cutting edge technology and has low manufacturing cost. This system is made up of two orthogonal pairs of pillow-shaped rollers that are located between flat bed and plates. By using this system in two ...

2005
Benjamin F. Chu-Kung Shyh-Chiang Shen Walid Hafez Milton Feng

GaAsSb/InP type-II transistors have been fabricated with fT > 325 GHz and fMAX > 275 GHz. This work will examine the layer structure design criteria allowing the fT to improve from 244 GHz to 358 GHz and the effects this has on the corresponding fMAX. Additionally, the process improvements to control the undercut into the active region during the base contact isolation etch will be discussed. T...

2009
Charudatta S. Mehendale Ian J. Fialho Karolos M. Grigoriadis CHARUDATTA S. MEHENDALE IAN J. FIALHO KAROLOS M. GRIGORIADIS

This paper presents a novel approach to the design of adaptive active vibration isolation systems using linear parameter-varying (LPV) control techniques. The proposed LPV controller is scheduled based on the relative position of the vibrating system, as well as a parameter that characterizes the harshness of the base motion. By scheduling on relative position, the controller is able to shift i...

2009
Ajay Sharma R. S. Jangid

Analytical seismic response of multi-story building supported on base isolation system is investigated under real earthquake motion. The superstructure is idealized as a shear type flexible building with lateral degree-of-freedom at each floor. The force-deformation behaviour of the isolation system is modelled by the bi-linear behaviour which can be effectively used to model all isolation syst...

2008
Y. Ribakov I. Iskhakov

As a rule, public buildings should have higher safety level compared to residential ones. Hence, using base isolation systems is an effective and widely known way for improving dynamic response of such buildings. The idea of base isolation was known hundreds years ago, however practical implementation of base isolators started in the last few decades. The main advantage of a base isolation syst...

Journal: :مهندسی سازه 0
علی بیرامی شهابی مجید برقیان

a new base isolation method for reducing the destructive effect of earthquake is proposed in this method mushroom shaped basements are used under structures as base isolation. these basements have spherical surface and are located on foundations. basements have pinned arms that are connected. when the length of the arm is less then the radius of spherical surface, the action of them is similar ...