نتایج جستجو برای: ascorbic acid determination
تعداد نتایج: 974390 فیلتر نتایج به سال:
a chemically modified carbon paste electrode with 2-chlorobenzoyl ferrocene (2cbf) and carbon nanotube (2cbfcnpe) was employed to study the electrocatalytic oxidation of ascorbic acid in aqueous solution using cyclic voltammetry, square wave voltammetry and chronoamperometry. the diffusion coefficient (d = 1.42 × 10-6 cm2 s-1), and the kinetic parameter such as the catalytic rate constant (k = ...
A flow injection method is reported for the determination of ascorbic acid based on amperometric detection, using a cobalt(II) phthalocyanine (CoPc) modified graphite-epoxy electrode. The amperometric respons was evaluated with regard to pH, ionic strength of the electrolyte, flow rate of the carrier solution, injected sample volume and conditioning time of the electrode. The limit of detec...
Poly (acridine red) modified glassy carbon electrode was used for the detection of dopamine in the presence of ascorbic acid in a pH 7.4 phosphate buffer solutions (PBS) by cyclic voltammetry and differential pulse voltammetry. The major difficulty of the overlapped oxidation potential of ascorbic acid could be overcome through the distinct attractive ability of poly (acridine red) film to cati...
This study compared the concentration of ascorbic acid between citrus fruits collected from the farm of Kerman in Iran. Determination of ascorbic acid was carried out using a liquid chromatography coupled to a diode array detector, with reverse phase and isocratic elution. The validation parameters showed efficiency, adequate linearity, relative standard deviation values 0.02 % (n=10) for repea...
The electrochemical behavior of ascorbic acid and uric acid on glassy carbon bare electrodes and ones modified with β-cyclodextrin entrapped in polyethyleneimine film has been investigated using square wave voltammetry. The electrode modification was achieved in order to separate the voltammetric peaks of ascorbic acid and uric acid when present in the same solution. On the modified electrodes ...
Erythromycin, phenazopyridine, methenamine mandelate, acetazolamide, and ascorbic acid reportedly interfere with the Porter-Silber reaction in the determination of urinary 17-hydroxycorticosteroids. Sodium bisulfite, added to the urine after hydrolysis with glucuronidase, removed almost all nonsteroidal interferences in urine from healthy adults medicated with the first three drugs, but such st...
A method of estimating the iron content of solutions containing haemoglobin, ferritin, or ferrioxamine is described. Iron is released by treatment with acid permanganate and ascorbic acid before conventional determination by an Auto Analyzer technique.
نمودار تعداد نتایج جستجو در هر سال
با کلیک روی نمودار نتایج را به سال انتشار فیلتر کنید