The calorimeter and muon systems are essential components to provide a trigger for the LHCb experiment. The calorimeter system comprises a scintillating pad detector and pre-shower, followed by electromagnetic and hadronic calorimeters. The calorimeter system allows photons, electrons and hadrons to be identified, and their energy to bemeasured. Themuon system consists of five measuring station...
The scintillator-strip electromagnetic calorimeter (ScECAL) is one of the calorimeter technologies which can achieve fine granularity required for the particle flow algorithm. Second prototype of the ScECAL has been built and tested with analog hadron calorimeter (AHCAL) and tail catcher (TCMT) in September 2008 at Fermilab meson test beam facility. Data are taken with 1 to 32 GeV of electron, ...
The concept of “particle flow” has been developed to optimise the jet energy resolution by distinguishing the different jet components. A highly granular calorimeter designed for the particle flow algorithm provides an unprecedented level of detail for the reconstruction of calorimeter showers and enables new approaches to shower analysis. In this paper the measurement and use of the fractal di...
The CALICE collaboration has constructed a highly granular hadronic calorimeter based on small scintillator tiles read out with silicon photomultipliers. With this detector, data was taken at CERN and at Fermilab. The high granularity of the detector allows the identification of minimum-ionizing track segments within hadronic showers, demonstrating the imaging capabilities of particle flow calo...
This note describes R&D to be carried out on the data acquisition system for a calorimeter at the future International Linear Collider. A generic calorimeter and data acquisition system is described. Within this framework modified designs and potential bottlenecks within the current system are described. Solutions leading up to a technical design report will to be carried out within CALICE-UK g...
The energy calibration of the two electromagnetic shower calorimeters (forward and large angle) of CLAS is proposed using the reaction p(e,e’p)π° like a uniform source of monochromatic pions. A preliminary study to understand the reaction kinematics, the energy range and the calibration feasibility as well as an estimate of the counting rate is presented. 1.1 F.E.S.C in CLAS The CLAS Forward an...
A measurement of the calorimeter response to isolated charged hadrons in the ATLAS detector at the LHC is presented. This measurement is performed with 3.2 nb[Formula: see text] of proton-proton collision data at [Formula: see text] [Formula: see text] from 2010 and 0.1 nb[Formula: see text] of data at [Formula: see text] [Formula: see text] from 2012. A number of aspects of the calorimeter res...
A quality control test is performed on nearly 2000 custom optical transmitters for use in the Liquid Argon Calorimeter of the ATLAS detector. More than 90% of these optical transmitters passed the test and have been installed in the calorimeter readout system. The acceptance criteria, measurement procedure, and results of the quality control test are presented in this note.
Beside the intrinsic characteristics of the CMS electromagnetic calorimeter components like crystal quality and APD performance, the wrapping of the crystals can have a impact on the overall calorimeter performance. The results of test measurements, which have been performed at PSI using different crystals and wrappings are reported and discussed.
A hodoscope calorimeter comprising of 704 lead-glass blocks is described. The calorimeter was constructed for use in the JLab Real Compton Scattering experiment. The detector provides a measurement of the coordinates and the energy of scattered photons in the GeV energy range with resolutions of 5 mm and 6%/ p Eγ [GeV ], respectively. Design features and performance parameters during the experi...