نتایج جستجو برای: cooling load
تعداد نتایج: 200733 فیلتر نتایج به سال:
This paper presents a robust hourly cooling-load forecasting method based on time-indexed autoregressive with exogenous inputs (ARX) models, in which the coefficients are estimated through a two-stage weighted least squares regression. The prediction method includes a combination of two separate time-indexed ARX models to improve prediction accuracy of the cooling load over different forecastin...
The impacts of ventilation ratio and vent balance on cooling load and air flow of naturally ventilated attics are studied in this paper using an unsteady computational fluid dynamics (CFD) model. Buoyancy-driven turbulent ventilations in attics of gable-roof residential buildings are simulated for typical summer conditions. Ventilation ratios from 1/400 to 1/25 combined with both balanced and u...
Component and subsystem models used to evaluate the performance of a low-lift cooling system are described. An air-cooled chiller, a hydronic radiant distribution system, variable-speed control, and peak-shifting controls are modeled. A variable-speed compressor that operates over 20:1 speed range and pressure ratios ranging from one to six is at the heart of the chiller. Condenser fan and chil...
Performance and economical efficiency of the combined cooling, heating and power (CCHP) system mainly depend on the system structure, operation strategy and choice of facility capacity. This paper proposes a structural configuration of the CCHP system with hybrid chillers, consisting of a combined electric and absorption chiller, whose electric cooling to cool load ratio varies according to dif...
If a current pulse with a magnitude several times higher than the steady state optimum current is applied to a thermoelectric cooler, an instantaneously lower temperature than that reachable at the steady state can be obtained. Most previous studies of this transient cooling effect focus on the minimum temperature achievable for free standing thermoelectric (TE) elements. In this work, we syste...
Selective emittance materials show high technical potential for use as radiative cooling heat exchangers for buildings. This paper presents the thermal modeling of the photonic radiative cooler and the simulation of a system that integrats the photonic radiative cooler with radiant floor cooling in a medium office building. The system was simulated with EnergyPlus and the extensive use of its e...
Electricity production in Lebanon stands at around 1.5 GW while the demand exceeds 2.5 GW at peak times and peak cooling demands, resulting in rationing cuts from between 3 to 20 hours a day which is the worst performance in the Middle East. Due to the country energy shortfall, a large number of small-scale backup generators is installed to address the electric and cooling needs. The proliferat...
Efficient scheduling of power generation, distribution, and usage are crucial for current and future smart grids. Improving the energy management in grid applications will benefit the wholesale electricity market as well as the consumers. This paper addresses the optimal power management problems in electric cooling systems based on appropriately constructed thermal dynamic models and cost prof...
نمودار تعداد نتایج جستجو در هر سال
با کلیک روی نمودار نتایج را به سال انتشار فیلتر کنید