نتایج جستجو برای: corneal thickness

تعداد نتایج: 134228  

Journal: :The British journal of ophthalmology 2001
A C Ventura R Wälti M Böhnke

BACKGROUND/AIMS Deturgescence of the corneal stroma is controlled by the pumping action of the endothelial layer and can be monitored by measurement of central corneal thickness (pachymetry). Loss or damage of endothelial cells leads to an increase in corneal thickness, which may ultimately induce corneal decompensation and loss of vision. Little is known about the effect of moderate reductions...

Journal: :The British journal of ophthalmology 2001
S W Chang I L Tsai F R Hu L L Lin Y F Shih

AIMS To further understand the effect of refractive error on the corneal dimensions and function. METHODS Corneal curvature, corneal thickness, and axial length measurements were performed, as well as specular microscopy and fluorophotometry, on patients with various refractive statuses. 216 subjects, mean age 22.2 (SD 4.2) years, were examined. Patients with previous contact lens wear histor...

Journal: :Archivos de la Sociedad Espanola de Oftalmologia 2009
J A Díaz-Rey M J Giráldez C García-Resúa E Yebra-Pimentel

OBJECTIVE To study the effect of 1 drop of combined topical anaesthesia (tetracaine 0.1% and oxybuprocaine 0.4%) on central corneal thickness (CCT) values and at 2.5 mm from the corneal centre in nasal, temporal, superior and inferior hemi meridians, monitored by Orbscan over a period of 16 minutes. MATERIALS AND METHODS The corneal thickness of 12 right eyes of 12 young healthy men was deter...

Journal: :Investigative ophthalmology & visual science 2005
Jost B Jonas Andrea Stroux Isabel Velten Anselm Juenemann Peter Martus Wido M Budde

PURPOSE To evaluate whether the amount of glaucomatous optic nerve damage at presentation of the patient and the rate of progression of glaucoma during follow-up are related to central corneal thickness. METHODS The prospective observational clinical study included 861 eyes of 454 white subjects (239 normal eyes of 121 subjects, 250 ocular hypertensive eyes of 118 patients, 372 eyes of 215 pa...

Journal: :Archivos de la Sociedad Espanola de Oftalmologia 2009
E Jiménez-Rodríguez M López-de-Cobos R Luque-Aranda M A López-Egea-Bueno A I Vázquez-Salvi J M García-Campos

OBJECTIVE to determine central corneal thickness in normal subjects, glaucomatous patients and ocular hypertension patients, to evaluate if the central corneal thickness is related to the presence of glaucoma or ocular hypertension. Furthermore, we aim to verify the relationship between central corneal thickness and severity of glaucomatous visual field loss. METHODS comparative study includi...

Journal: :Investigative ophthalmology & visual science 2003
Jianhua Wang Desmond Fonn Trefford L Simpson

PURPOSE To determine changes in topographical thickness of the epithelium and total cornea after hydrogel (2-hydroxyethyl methacrylate; HEMA or soft lens) and PMMA rigid contact lens wear with eyes closed, as measured by optical coherence tomography (OCT). METHODS Epithelial and total corneal thickness in 18 neophyte eyes was measured with OCT at intervals of 10 degrees across a 10-mm zone of...

Journal: :The British journal of ophthalmology 1983
S E Nilsson J A Morris

A high water content lens (Scanlens 75, +14.5 dioptres) and a low water content lens (Bausch and Lomb Soflens H3, +14.5 dioptres) were compared with respect to corneal thickness response after 6 hours of wear in a provocative test on 12 aphakic eyes. The mean increase in central corneal thickness was 3.3% for Scanlens and 6.4% for Soflens. This difference is statistically highly significant (p ...

2017
Katarzyna Krysik Dariusz Dobrowolski Katarzyna Polanowska Anita Lyssek-Boron Edward A Wylegala

PURPOSE Comparative analysis of central and peripheral corneal thickness in PEX patients using three different imaging systems: Pentacam-Scheimpflug device, time-domain optical coherence tomography (OCT) Visante, and swept-source OCT Casia. MATERIALS AND METHODS 128 eyes of 80 patients with diagnosed PEX were examined and compared with 112 normal, non-PEX eyes of 72 cataract patients. The stu...

Journal: :بینا 0
محمدمهدی صدوقی mm sadoughi ophthalmic research center, shahid beheshti university of medical sciences, tehran, iranتهران- پاسداران- بوستان نهم- خیابان پایدارفرد (خیابان امیر ابراهیمی)- پلاک 23- مرکز تحقیقات چشم علیرضا برادران رفیعی a baradaran-rafii ophthalmic research center, shahid beheshti university of medical sciences, tehran, iranتهران- پاسداران- بوستان نهم- خیابان پایدارفرد (خیابان امیر ابراهیمی)- پلاک 23- مرکز تحقیقات چشم مهدی اصلانی m eslani ophthalmic research center, shahid beheshti university of medical sciences, tehran, iranتهران- پاسداران- بوستان نهم- خیابان پایدارفرد (خیابان امیر ابراهیمی)- پلاک 23- مرکز تحقیقات چشم فرید کریمیان f karimian ophthalmic research center, shahid beheshti university of medical sciences, tehran, iranتهران- پاسداران- بوستان نهم- خیابان پایدارفرد (خیابان امیر ابراهیمی)- پلاک 23- مرکز تحقیقات چشم حامد اسفندیاری h esfandiari ophthalmic research center, shahid beheshti university of medical sciences, tehran, iranتهران- پاسداران- بوستان نهم- خیابان پایدارفرد (خیابان امیر ابراهیمی)- پلاک 23- مرکز تحقیقات چشم شهرام صالحی راد sh salehirad ophthalmic research center, shahid beheshti university of medical sciences, tehran, iranتهران- پاسداران- بوستان نهم- خیابان پایدارفرد (خیابان امیر ابراهیمی)- پلاک 23- مرکز تحقیقات چشم

purpose: to compare outcomes of two techniques (anwar vs. melles) of deep anterior lamellar keratoplasty (dalk) in patients with keratoconus. methods: this randomized double-blind clinical trial was performed on 57 eyes of 57 patients with keratoconus. patients aged 20-35 years with a clinical diagnosis of keratoconus who were contact lens intolerant and had corrected distance visual acuity (cd...

Journal: :Eye & contact lens 2011
Javier González-Pérez Jose M González-Méijome María T Rodríguez Ares Manuel A Parafita

PURPOSE To evaluate the effect of an acoustic factor (AF) on the comparison of central corneal thickness (CCT) and peripheral corneal thickness (PCT) measurements with Orbscan II and Pentacam. METHODS The CCT and PCT at 1, 2, and 3 radial distances from the corneal apex were measured using Orbscan II and Pentacam in 22 right eyes of 22 healthy adults (7 men, 15 women). Three measures were obt...

نمودار تعداد نتایج جستجو در هر سال

با کلیک روی نمودار نتایج را به سال انتشار فیلتر کنید