نتایج جستجو برای: deformed rebar
تعداد نتایج: 14990 فیلتر نتایج به سال:
Repair mortar is commonly used to rehabilitate reinforced concrete structures or components that exhibit a relatively high level of distresses. Yet, the repair mortar can be contaminated by salt from its service environment. This work employs a two-dimensional finite element model to investigate the non-stationary transport behavior of ionic species in salt-contaminated and water-saturated repa...
We report remote strain and displacement measurement during elastic and plastic deformation using a metamaterial-based wireless and passive sensor. The sensor is made of a comb-like nested split ring resonator (NSRR) probe operating in the near-field of an antenna, which functions as both the transmitter and the receiver. The NSRR probe is fixed on a standard steel reinforcing bar (rebar), and ...
A Beam Test Study on the Bond Performance between Epoxy-Coated Reinforcement and Geopolymer Concrete
An epoxy-coated reinforcement geopolymer concrete structure with good durability and energy-saving properties can be formed by combining concrete. The bond strength is the precondition for two to work together. In this paper, 13 beam specimens (11 reinforcements 2 ordinary deformed reinforcements) were designed investigate influence of concrete, diameter reinforcement, bonding length type on pe...
Rebar fracture in boundary elements of lightly reinforced shear walls in recent earthquake motivated research on the minimum longitudinal reinforcement applicable to shear walls. These researches lead to change in the ACI 318-19 requirement for minimum longitudinal reinforcement in boundary elements. New ACI 318 requirement increase minimum longitudinal reinforcement ratio for boundary elements...
To explore the feasibility of improving the delivery process of reinforced concrete, we focus in this paper on reinforcing bars (rebar) used in cast-in-place (CIP) concrete. Specifically, we describe the methodology for set-based design of rebar that we are pursuing in an ongoing research effort. Set-based design makes it possible to maintain feasible solutions for longer in the design process ...
Borated water leakage through spent fuel pools (SFPs) at pressurized water reactors is a concern because it could cause corrosion of reinforcement steel in the concrete structure and compromise the integrity of the structure. Because corrosion rate of carbon steel in concrete in the presence of boric acid is lacking in published literature and available data are equivocal on the effect of boric...
This study investigated the response of reinforced concrete (RC) slabs in building structures to internal explosions. The performances of two slabs designed in accordance with the protective structural design and conventional gravity design approaches were evaluated in terms of midspan displacements, support rotations, and damage patterns. Data from available slab blast experiments in the open ...
Senior Associate Vice President for Research Executive Director, Discovery Park Purdue University Hovde Hall, Room 332 610 Purdue Mall West Lafayette, IN 47907-2040 [email protected] Rose E. Raskin, DVM, PhD, Diplomate ACVP Professor of Veterinary Clinical Pathology Dept of Veterinary Pathobiology Purdue University School of Veterinary Medicine 725 Harrison Street West Lafayette, IN 47907 rraski...
In this paper, a novel kind of method to monitor corrosion expansion of steel rebars in steel reinforced concrete structures named fiber optic coil winding method is proposed, discussed and tested. It is based on the fiber optical Brillouin sensing technique. Firstly, a strain calibration experiment is designed and conducted to obtain the strain coefficient of single mode fiber optics. Results ...
نمودار تعداد نتایج جستجو در هر سال
با کلیک روی نمودار نتایج را به سال انتشار فیلتر کنید