نتایج جستجو برای: detector response

تعداد نتایج: 1031397  

2008
M Rakhmanov J D Romano J T Whelan

Abstract Searches for gravitational waves with km-scale laser interferometers often involve the long-wavelength approximation to describe the detector response. The prevailing assumption is that the corrections to the detector response due to its finite size are small and the errors due to the long-wavelength approximation are negligible. Recently, however, Baskaran and Grishchuk (2004 Class. Q...

1990
Douglas B. Thomas Edward F. Zalewski

A total of fifteen laboratories participated in the CIE detector response in-tercomparison which was designed to assess the level of agreement among participating laboratories in the absolute measurement (with respect to SI) of photodetector response in the visible spectral region. Most participants were either commercial laboratories or university laboratories with the National Institute of St...

Journal: :The Review of scientific instruments 2007
Ikuo Kanno Shigeomi Hishiki Yoshitaka Kogetsu Tatsuya Nakamura Masaki Katagiri

An InSb Schottky detector, fabricated from an undoped InSb wafer with Hall mobility which is higher than those of previously employed InSb wafers, was used for alpha particle detection. The output pulse of this InSb detector showed a very fast rise time, which was comparable with the output pulses of scintillation detectors.

Journal: :Medical physics 2012
I Ciancaglioni Marco Marinelli E Milani G Prestopino C Verona G Verona-Rinati R Consorti A Petrucci F De Notaristefani

PURPOSE To determine the potentialities of synthetic single crystal diamond Schottky diodes for accurate dose measurements in radiation therapy small photon beams. METHODS The dosimetric properties of a diamond-based detector were assessed by comparison with a reference microionization chamber. The diamond device was operated at zero bias voltage under irradiation with high-energy radiotherap...

1998
Y. Zong R. U. Datla

A bolometer detector system was developed for the high accuracy infrared spectrophotometer at the National Institute of Standards and Technology to provide maximum sensitivity, spatial uniformity, and linearity of response covering the entire infrared spectral range. The spatial response variation was measured to be within 0.1 %. The linearity of the detector output was measured over three deca...

2014
Wei Loong Jong Jeannie Hsiu Ding Wong Ngie Min Ung Kwan Hoong Ng Gwo Fuang Ho Dean L. Cutajar Anatoly B. Rosenfeld

In vivo dosimetry is important during radiotherapy to ensure the accuracy of the dose delivered to the treatment volume. A dosimeter should be characterized based on its application before it is used for in vivo dosimetry. In this study, we characterize a new MOSFET-based detector, the MOSkin detector, on surface for in vivo skin dosimetry. The advantages of the MOSkin detector are its water eq...

2009
G. Naumenko O. Grimm V. Cha

Room-temperature detector, manufactured by the company ‘‘SPINOR’’ (Tomsk Russia) was tested for the investigations of the coherent synchrotron radiation characteristics at the bent electron beam of FLASH (Hamburg) in the wavelength region 0.5–3mm. Detector is based on a low-threshold diode and a broadband antenna with a built-in preamplifier. The detector characteristics allowed us to measure a...

2003
D V Averin

Linear response theory describes quantum measurement with an arbitrary detector weakly coupled to a measured system. This description produces generic quantitative relation characterizing the detector that is analogous to the fluctuation-dissipation theorem for equilibrium systems. The detector characteristic obtained in this way shows how efficient the trade-off is between the back-action deph...

2005
Andrzej Odon

Voltage response of a designed and constructed pyroelectric PVDF detector to pulse radiation was experimentally investigated. The detector performance has been tested and its time parameters, response linearity as a function of energy and width of optical pulses, frequency response and temperature characteristics were determined.

نمودار تعداد نتایج جستجو در هر سال

با کلیک روی نمودار نتایج را به سال انتشار فیلتر کنید