نتایج جستجو برای: device removal

تعداد نتایج: 806947  

Orthopedic implant removal is a commonly performed procedure. While implant removal can be associated withimproved symptoms, risks of the surgery are notable. Stripped screws, broken and retained hardware, and morbidityassociated with soft tissue compromise during difficult removal are all common. Familiarity with the instruments iscritical to procedure success. The purpose of...

Journal: :Gynecologie, obstetrique & fertilite 2013
A-S Tholozan J J Terzibachian A Bourtembourg F Leung A Atassi P Kouakou R Maillet D Riethmuller

Genital-pelvic actinomycosis is an uncommon disease which often arises on women with long term use of intrauterine device. Its diagnostic remains difficult. Even if different clinical locations has been reported, location to the psoas muscle is exceptional. We report such a case, diagnosed on a 53 years old woman. Both a tumoral and a severe infectious syndrome appeared three months after an in...

Journal: :Pediatrics 2014
Anna Cavigelli-Brunner Martin Schweiger Walter Knirsch Brian Stiasny Karin Klingel Oliver Kretschmar Michael Hübler

This report describes an 8-year-old child with acute anthracycline-induced cardiomyopathy triggered by human herpesvirus 6 and the subsequent implantation of an intracorporeal continuous-flow left ventricular assist device (LVAD) and the process to discharge the child from the hospital. After barely 3 months on mechanical support, the device was explanted after thorough examination. Experiences...

Journal: :AJNR. American journal of neuroradiology 2008
W P Daugherty J B White H J Cloft D F Kallmes

This report describes the cases of 2 patients with failed retrieval of an AngioGuard distal protection device after carotid stent placement with rescue retrieval by use of a vertebral catheter. An AngioGuard was deployed before carotid angioplasty and stent placement. Attempted removal of the device with the provided recapture sheath was unsuccessful. A 5F 120-cm vertebral catheter was used to ...

Journal: :Antimicrobial agents and chemotherapy 2013
Jop Jans Roger J M Brüggemann V Christmann Paul E Verweij Adilia Warris

Invasive Candida infections associated with medical devices are very difficult to cure without device removal. We present a case of neonatal cerebrospinal fluid shunt-associated Candida meningitis, in which removal of the device was precluded, that was successfully treated with caspofungin. Pharmacokinetic assessment of caspofungin concentrations in cerebrospinal fluid showed that exposure was ...

Journal: :Journal of vascular and interventional neurology 2014
Bartley Mitchell Liang-Der Jou Michel Mawad

BACKGROUND Flow-diverter stents are increasingly being used in the endovascular treatment of intracranial aneurysms. Because of this increased usage, the occurrence of stent malpositioning, intra-arterial distortion, or migration will likely increase as well. METHODS We describe the conformational twisting and deformity of a pipeline embolic device (PED) stent (Covidien, EV3) within the carot...

Journal: :JSLS : Journal of the Society of Laparoendoscopic Surgeons 2014

نمودار تعداد نتایج جستجو در هر سال

با کلیک روی نمودار نتایج را به سال انتشار فیلتر کنید