نتایج جستجو برای: dialysate

تعداد نتایج: 2491  

Journal: :Journal of the American Society of Nephrology : JASN 2004
Ralf Schindler Werner Beck Reinhold Deppisch Mario Aussieker Adelheid Wilde Hermann Göhl Ulrich Frei

A number of bacterial cytokine-inducing substances (CIS) such as lipopolysaccharides (LPS) and exotoxins have been detected in dialysate and may contribute to inflammation in hemodialysis patients. Short DNA fragments, oligodeoxynucleotides (ODN) of 6 to 20 nucleotides, are able to bind to Toll-like receptors and are stimulatory on immune cells. ODN induce natural killer cell activity and induc...

Journal: :Archives of disease in childhood 1999
A Kamel S Norgren B Persson C Marcus

AIMS To investigate the dynamics between plasma and dialysate glucose during hypoglycaemia in children. STUDY DESIGN Six children in prepuberty or early puberty were investigated by multiple blood sampling and microdialysis of subcutaneous adipose tissue during a standard arginine-insulin tolerance test. Glucose and glycerol, as an index of lipolysis, were measured in samples from both compar...

Journal: :Mediators of Inflammation 2007
H. L. Tjiong F. J. Zijlstra T. Rietveld J. L. Wattimena J. G. M. Huijmans G. R. Swart M. W. J. A. Fieren

OBJECTIVES Protein-energy malnutrition as a consequence of deficient protein intake frequently occurs in peritoneal dialysis (PD) patients. Previously, we showed that peritoneal dialysate containing a mixture of amino acids (AA) and glucose has anabolic effects. However AA-dialysate has been reported to increase intraperitoneal protein and AA losses and the release of proinflammatory cytokines ...

2014
Kuan-Yu Hung Shin-Yun Liu Te-Cheng Yang Tien-Ling Liao Shu-Huei Kao

Human peritoneal mesothelial cells (HPMCs) are a critical component of the peritoneal membrane and play a pivotal role in dialysis adequacy. Loss of HPMCs can contribute to complications in peritoneal dialysis. Compelling evidence has shown that high-dialysate glucose is a key factor causing functional changes and cell death in HPMCs. We investigated the mechanism of HPMC apoptosis induced by h...

Journal: :Hemodialysis international. International Symposium on Home Hemodialysis 2006
Nigel Toussaint Patrick Cooney Peter G Kerr

The dialysate calcium (Ca) concentration for hemodialysis (HD) patients can be adjusted to manage more optimally the body's Ca and phosphate balance, and thus improve bone metabolism as well as reduce accelerated arteriosclerosis and cardiovascular mortality. The appropriate dialysate Ca concentration allowing this balance should be prescribed to each individual patient depending on a multitude...

Journal: :Nephron 1990
R Marcen L Orofino C Quereda J Pascual J Ortuño

R. Marcen, Servicio de Nefrología, Hospital Ramon Y Cajal, Ctra Colmenar Viejo, Km 9.1, E-28034 Madrid (Spain) Dear Sir, In a previous double-blind short-term study [1], we observed the beneficial effects of cool dialysate on hemo-dialysis-induced symptoms in a group of selected patients with frequent episodes of symptomatic hypotension (SH). Later on, those results were confirmed when using co...

Journal: :Nephrology, dialysis, transplantation : official publication of the European Dialysis and Transplant Association - European Renal Association 1998
V Panichi S De Pietro B Andreini M Migliori V Tessore D Taccola P Rindi R Palla C Tetta

BACKGROUND Bacterial contamination of dialysate may enhance cytokine production in haemodialysis. We tested the hypothesis that intracellular cytokines could be enhanced in a large group of patients exposed to backfiltration of dialysate over a long period of observation. METHODS The intracellular cytokine (interleukin-1 receptor antagonist and interleukin-1beta) concentrations in chronic ura...

Journal: :Clinical journal of the American Society of Nephrology : CJASN 2006
Robert M Lindsay Jan Sternby Bo Olde Roland Persson Mary Ellen Thatcher Kim Sargent

Measurement of blood flow rate (Qa) is used to monitor arteriovenous fistulas and grafts that are used for hemodialysis blood access. Most Qa measurements use indicator dilution techniques to measure the recirculation that is induced by the reversal of hemodialysis blood lines. R plus the dialysis circuit flow (Qb) allows the calculation of Qa. The principle of needle reversal also can be used ...

2016
Sigrid Kalle Risto Tanner Jürgen Arund Ruth Tomson Merike Luman Ivo Fridolin

AIM In this work we estimated the contribution of the fluorescence of 4-pyridoxic acid (4-PA) to the total fluorescence of spent dialysate with the aim of evaluating the on-line monitoring of removal of this vitamin B-6 metabolite from the blood of patients with end-stage renal disease (ESRD). METHODS Spectrofluorometric analysis of spent dialysate, collected from hemodialysis and hemodiafilt...

Journal: :Computer methods and programs in biomedicine 1990
E Akcahuseyin H H Vincent F J van Ittersum W A van Duyl M A Schalekamp

Continuous arterio-venous hemodiafiltration (CAVHD) differs from conventional hemofiltration and dialysis by the interaction of convection and diffusion, the use of very low dialysate flow rates and by the deterioration of membrane conditions during the treatment. In order to study the impact of these phenomena on diffusive transport, we developed a mathematical model of the kinetics of CAVHD s...

نمودار تعداد نتایج جستجو در هر سال

با کلیک روی نمودار نتایج را به سال انتشار فیلتر کنید