نتایج جستجو برای: diamond dosimeter

تعداد نتایج: 23066  

2014
S. M. Gafar

In this study the spectrophotometric response of the Toluidine Blue O (TBO)-gelatin gel dosimeter irradiated with gamma rays was characterized. Preparation of dyed-gelatin gel takes place in neutral medium; to give eventually gel dosimeter has a sharp absorbance peak at 635 nm that bleaches quantitatively upon irradiation and the colour change can be measured with UV-VIS spectrophotometer. The ...

2017
Heather M Whitney Daniel F Gochberg C Waldenberg A Karlsson Hauer

The normoxic polymer gel dosimeter based on N-isopropyl acrylamide (NiPAM) is a promising full 3D-dosimeter with high spatial resolution and near tissue equivalency. NiPAM gel samples were irradiated to different doses using a linear accelerator. The absorbed dose was evaluated using MRI and statistical significance of the analysed data was calculated. The analysis was carried out using an in-h...

2002
W Czarnowski B Wielgomas J Krechniak

A passive dosimeter designed to measure exposure to hydrogen fluoride was tested under laboratory conditions over the concentration range of 0.56 – 4.47 mg HF/m. The lowest concentration was chosen to be close to the Polish TLV (0.5 mg HF/m). The dosimeter consists of a Whatman No.1 filter paper impregnated with K2HPO4 placed in a polyethylene holder protected by a polyethylene screen. After ex...

2002
David Banaszak

The Air Force sponsored flight tests using damage dosimeters, fabricated by The Boeing Company, to measure temperature and structural dynamic strains on B-52, F-15 and C-130 aircraft. The dosimeter measurements help diagnose difficultto-analyze structural conditions, such as acoustics and high cycle fatigue, and support the durability patch design process to repair secondary structure cracks. T...

2013
Ivan Buzurovic Timothy N. Showalter Matthew T. Studenski Robert B. Den Adam P. Dicker Junsheng Cao Ying Xiao Yan Yu Amy Harrison

In this article we describe commissioning and implementation procedures for the Dose Verification System (DVS) with permanently implanted in vivo wireless, telemetric radiation dosimeters for absolute dose measurements. The dosimeter uses a semiconductor device called a metal-oxide semiconductor field-effect transistor (MOSFET) to measure radiation dose. A MOSFET is a transistor that is general...

Two types of micron-diamond films were prepared on YG6 substrate by hot filament chemical vapor deposition(HFCVD) method. Morphology and orientation of crystalline growth were evaluated by SEM and XRD. Diamond film coated tools and sapphire wafer’ surface before and after lapping experiment  were contrasted. The results indicated that a significant change in Raman spectrum of two types of micro...

Journal: :Medical physics 2000
G I Kaplan A B Rosenfeld B J Allen J T Booth M G Carolan A Holmes-Siedle

Measurement of the lateral profile of the dose distribution across a narrow x-ray microbeam requires a dosimeter with a micron resolution. We investigated the use of a MOSFET dosimeter in an "edge-on" orientation with the gate insulating oxide layer parallel to the direction of the beam. We compared results using this technique to Gafchromic film measurements of a 200 micrometer wide planar x-r...

Journal: :Spectrochimica acta. Part A, Molecular and biomolecular spectroscopy 2008
M Danilczuk H Gustafsson M D Sastry E Lund A Lund

Polycrystalline ammonium dithionate has been examined for its radiation response in the low dose range (<5Gy) using EPR technique. The SO(3)(-) radical ion was detected as a single EPR line with a peak-to-peak derivative width of ca. 0.44mT in irradiated samples and its intensity was found to vary linearly with dose. At equal and moderate settings of microwave power and modulation amplitude amm...

Journal: :Photochemical & photobiological sciences : Official journal of the European Photochemistry Association and the European Society for Photobiology 2010
Keqin Jia Alfio V Parisi Michael G Kimlin

This paper provides an overview of the characteristics of a phenothiazine-mylar dosimeter which can be used as an effective solar UVA exposure assessment tool. This dosimeter is sensitive to UVA wavelengths (315-400 nm); its performance has been characterized in a series of tests such as (a) UVA exposure response (dose-response), (b) temperature stability of the response, (c) impact of long ter...

Journal: :Journal of Radioanalytical and Nuclear Chemistry 2022

Abstract Three different dosimetry systems were prepared based on diphenyl thiocarbazone (DTH) dye: polymer films made with, poly(vinyl alcohol), DTH liquid dosimeter and gel dosimeter. All the received several gamma doses. The three analyzing by UV–Vis spectrophotometery before after irradiation. effective dose range in linear part of these is between 1–10 kGy, 0.3–2 50–200 Gy. dosimeters reli...

نمودار تعداد نتایج جستجو در هر سال

با کلیک روی نمودار نتایج را به سال انتشار فیلتر کنید