نتایج جستجو برای: dose optimization

تعداد نتایج: 624710  

ژورنال: سنجش و ایمنی پرتو 2020

Radiation therapy, is one of the treatments for cancer. Brachytherapy is a radiotherapeutic technique that a sealed radiation source is placed inside or next to the tissue and has become a mainstream treatment option for cancer. Achieving maximum dose to the gland as well as minimum injury to the adjacent tissues is a basic principle in radiation therapy. Sources configuration must be designed ...

ژورنال: سنجش و ایمنی پرتو 2013

Optimization in radiotherapy is one of an important and attractive topic in Medical Physics. In this study, we have written a computer code base on genetic algorithm using MATLAB software, to optimize the best places of brachytherapy sources with optimal value of a parameter which is determined by weight. The weight parameter is related to the activity of each seed implant brachytherapy sources...

Journal: :Journal of the Belgian Society of Radiology 2017

Journal: :journal of biomedical physics and engineering 0
d khoshdel-navi school of medicine, babol university of medical sciences, babol, iran a shabestani-monfared department of medical physics, faculty of medicine, babol university of medical sciences, babol, iranسازمان اصلی تایید شده: دانشگاه علوم پزشکی بابل (babol university of medical sciences) m r deevband 3department of medical physics, school of medicine, shahid beheshti university of medical sciences, tehran, iranسازمان اصلی تایید شده: دانشگاه علوم پزشکی بابل (babol university of medical sciences) r abdi department of radiology, mazandaran university of medical sciences, sari, iranسازمان اصلی تایید شده: دانشگاه علوم پزشکی شهید بهشتی (shahid beheshti university of medical sciences) m nabahati department of radiology, babol university of medical sciences, babol, iranسازمان اصلی تایید شده: دانشگاه علوم پزشکی مازندران (mazandaran university of medical sciences)

background: the most efficient application of ionizing radiation is serving medical purposes and using this radiation has caused people to learn that artificial sources of radiation exposure among these resources can be of highest exposure rate.   objective: the present study is aimed at initially establishing a baseline for local-reference dose level in mazandaran, iran in 12 projections of th...

Journal: :AJR. American journal of roentgenology 2013
Elena Tonkopi Andrew A Ross Anita MacDonald

OBJECTIVE. The objective of this study was to optimize CT protocols for whole-body PET/CT by reducing radiation dose while minimizing effects on image quality. MATERIALS AND METHODS. Before protocol optimization, a survey of 140 consecutive patients was conducted to establish the baseline dose from a whole-body PET/CT examination. Another sample of 100 patients was surveyed to evaluate the redu...

2009
Albert S. Zacarias Michael D. Mills

IMRT plans generated in Eclipse use a fast algorithm to evaluate dose for optimization and a more accurate algorithm for a final dose calculation, the Analytical Anisotropic Algorithm. The use of a fast optimization algorithm introduces optimization convergence errors into an IMRT plan. Eclipse has a feature where optimization may be performed on top of an existing base plan. This feature allow...

Journal: :Medical physics 2012
W Liu X Zhu X Li Y Li X Zhang S Frank R Mohan

PURPOSE Robust optimization leads to IMPT plans that are more robust than and superior in optimality compared to PTV-based optimized plans. Robust optimization incorporates setup and range uncertainties, which implicitly adds margins to targets and organs-at-risk (OARs); whereas PTV-based optimization only considers setup uncertainties and adds margins only to targets in practice. The purpose o...

نمودار تعداد نتایج جستجو در هر سال

با کلیک روی نمودار نتایج را به سال انتشار فیلتر کنید