نتایج جستجو برای: dosimetry linear accelerator add on mlc recommissioning
تعداد نتایج: 8622156 فیلتر نتایج به سال:
background: accurate small radiation field dosimetry is essential in modern radiotherapy techniques such as stereotactic radiosurgery (srs) and intensity modulated radiotherapy (imrt). precise measurement of dosimetric parameters such as beam profile, percentage depth doses and output factor of these beams are complicated due to the electron disequilibrium and the steep dose gradients. in the p...
In the present study, we describe a method based on the analysis of the dynamic MLC log files (DynaLog) generated by the controller of a Varian linear accelerator in order to perform patient-specific IMRT QA. The DynaLog files of a Varian Millennium MLC, recorded during an IMRT treatment, can be processed using a MATLAB-based code in order to generate the actual fluence for each beam and so rec...
background: the purpose of this study was to investigate the application of the monte carlo technique to calculate and analysis of dosimetric parameters for electron beams used in radiotherapy. this technique is based on statistical method and has a powerful role in different radiotherapy aspects. materials and methods: the simulated medical linear accelerator was the varian clinac 2100c. the e...
The Brazilian Institute of Radiation Protection and Dosimetry (IRD/CNEN) carried out quality assurance regulatory audits in Brazilian radiotherapy facilities from 1995 to 2007. In this work, the set of data collected from 195 radiotherapy facilities that use high-energy photon beams are analyzed. They include results from audits in linear electron accelerators and/or Co-60 units. The inspectors...
Background: Small-field dosimetry remains an open challenge globally. Thus, it is crucial to consider adequate reference codes of practice for the performance dosimetry. Furthermore, as part good clinical practice, implementation new implies development a audit program. In this work, pilot dosimetric protocol established measuring absolute dose in water small fields using micro-TLDs LiF:Mg,Ti d...
PURPOSE Advanced radiotherapy delivery systems designed for high-dose, high-precision treatments often come equipped with high-definition multi-leaf collimators (HD-MLC) aimed at more finely shaping radiation dose to the target. In this work, we study the effect of a high definition MLC on spine stereotactic body radiation therapy (SBRT) treatment plan quality and plan deliverability. METHODS...
The task group (TG) for quality assurance of medical accelerators was constituted by the American Association of Physicists in Medicine's Science Council under the direction of the Radiation Therapy Committee and the Quality Assurance and Outcome Improvement Subcommittee. The task group (TG-142) had two main charges. First to update, as needed, recommendations of Table II of the AAPM TG-40 repo...
Radiation effects of photon irradiation in Ytterbium-doped silica optical fibers are still much less explored despite their importance in space-based application as radiation dosimetry. This study investigates and compares the thermoluminescence glow curve, response, linearity and sensitivity of Ytterbium-doped SiO2 optical fibers with that of TLD-100. Samples are placed in solid phantom and ir...
Various neutron detectors for spectrometry, environmental dosimetry and personal dosimetry have been developed by our group. For high energy neutron spectrometry, spallation detectors of C and Bi, large plastic and NE-213 scintillators, self TOF detector have been used for neutron production and shielding experiments at several high energy accelerator facilities, ISIS of Rutherford Appleton Lab...
We investigated the ferrous sulfate-benzoic acid-xylenol orange (FBX) aqueous chemical dosimeter for measurement of virtual (dynamic) wedge profiles on a linear accelerator. The layout for irradiation of the FBX-filled tubes mimicked a conventional linear detector array geometry. A comparison of the resulting measurements with film-measured profiles showed that, in the main beam region, the dif...
نمودار تعداد نتایج جستجو در هر سال
با کلیک روی نمودار نتایج را به سال انتشار فیلتر کنید