Journal: :Journal of Luminescence 2021

Autzen et al. (2018) observed a decrease in quartz luminescence at very high doses (several MGy) and hypothesised that this was linked to reduction the trapped hole population as result of their silt-sized grains (̴50 μm diameter) retaining excess electrons during irradiation. In paper, we expand on simulations (2017) [1] cover both natural laboratory irradiations for first time couple output ra...

2006
ANATOLY B. ROSENFELD

Semiconductor radiation detectors play an important role in radiation instrumentation. They have many advantages due to their small size, outstanding energy resolution in nuclear spectroscopy, easy pixilation for high spatial resolution and ability of integration with readout electronics. Advancement in microelectronic industry made silicon one of the most popular material for radiation detecto...

Journal: :International journal of radiation biology 2017
François Trompier Christopher Burbidge Céline Bassinet Marion Baumann Emanuela Bortolin Cinzia De Angelis Jonathan Eakins Sara Della Monaca Paola Fattibene Maria Cristina Quattrini Rick Tanner Albrecht Wieser Clemens Woda

PURPOSE In the EC-funded project RENEB (Realizing the European Network in Biodosimetry), physical methods applied to fortuitous dosimetric materials are used to complement biological dosimetry, to increase dose assessment capacity for large-scale radiation/nuclear accidents. This paper describes the work performed to implement Optically Stimulated Luminescence (OSL) and Electron Paramagnetic Re...

Journal: :Medical physics 2012
S Tanny B Gautam D Pearson E Parsai

PURPOSE Solid state detectors from two independent systems have shown similar over-responses to small electron fields used for treatment of surface lesions. We propose to evaluate the accuracy of solid state detector systems for highly blocked electron fields as a method for clinical dosimetry and determine the cause for any deviations from expected dose-delivery calculations. METHODS A QED D...

Journal: :iranian journal of radiation research 0
s. abdollahi reza radiotherapy oncology center, mashhad, iran m. mohammadi department of medical physics, hamadan university of medical science, hamadan, iran a. ebrahimzadeh pezeshki reza radiotherapy oncology center, mashhad, iran z. alizadeh reza radiotherapy oncology center, mashhad, iran

background: in order to deliver the precise dose to the target in radiotherapy, absorbed dose to water at the reference point should be assessed. when the calibration procedure is performed for a reference dosimeter in the 60co beam of a secondary standard dosimetry laboratory (ssdl), the total uncertainty in absorbed dose to water (dw) is estimated to be approximately 1.5%. this study attempts...

Journal: :Radiotherapy and oncology : journal of the European Society for Therapeutic Radiology and Oncology 1998
A Nisbet D I Thwaites M E Sheridan

BACKGROUND AND PURPOSE A comprehensive dosimetry intercomparison has been carried out involving all the radiotherapy centres, all external beam modalities and every radiotherapy treatment unit in the Republic of Ireland. MATERIALS AND METHODS Reference point measurements were made for all megavoltage photon beams. Doses were also investigated in planned three-field distributions. One of these...

2015
Raffaele Liuzzi Federica Savino Vittoria D’Avino Mariagabriella Pugliese Laura Cella Gabriele Multhoff

BACKGROUND Purpose of the present work was to investigate thermoluminescent dosimeters (TLDs) response to intraoperative electron radiation therapy (IOERT) beams. In an IOERT treatment, a large single radiation dose is delivered with a high dose-per-pulse electron beam (2-12 cGy/pulse) during surgery. To verify and to record the delivered dose, in vivo dosimetry is a mandatory procedure for qua...

Journal: :iranian journal of radiation research 0
n. jabbari department of medical physics and imaging, urmia university of medical sciences, urmia, iran h. nedaie department of radiotherapy, cancer institute, tehran university of medical science, tehran, iran a. zeinali department of medical physics and imaging, urmia university of medical sciences, urmia, iran

background: understanding of the incident electron energy and angular distributions from clinical electron accelerators (linacs) is important for dosimetry and treatment planning. the most important goals of this study were to evaluate the energy fluence and angular distributions of electron beams from a neptun 10pc linac using the monte carlo (mc) code. materials and methods: the linac electro...

Hamid Reza Baghani, Mostafa Robatjazi, Seyed Rabi Mahdavi

Introduction: Intraoperative radiotherapy is a radiotherapy technique in which a high single fraction of radiation dose is delivered to the patient after surgery and Concurrent with anesthesia time. The most frequent method for IORT implementation is Intraoperative electron radiotherapy (IOERT), in which, some dedicated and high dose per pulse electron accelerators are employe...