Introduction: Radiation therapy involves a multistep procedure; therefore, the error in patient set up is an inherent part of the treatment. Main purpose of this study was to determine the clinical target volume (CTV) to planning target volume (PTV) in head and neck cancer patients. Material and Methods: A total of 15 patients who had daily p...
The importance of medical physics methods in modern radiation therapy is shown. types irradiation used are considered. At each stage, it necessary to maintain high accuracy all procedures. One the significant stages treatment planning, where quality control plan carried out ensure patient. process plans with intensity modulation (Volumetric Modulated Arc Therapy - VMAT) on VitalBeam linear acce...
In intensity modulated radiation treatments (IMRT), the position of the field edges and the modulation within the beam are often achieved with a multileaf collimator (MLC). During the MLC calibration process, due to the finite accuracy of leaf position measurements, a systematic error may be introduced to leaf positions. Thereafter leaf positions of the MLC depend on the systematic error introd...
A model has been developed to describe the sampling process that occurs when intensity modulated radiotherapy treatments (delivered with a multileaf collimator) are imaged with an electronic portal imaging device that acquires a set of frames with a finite dead-time between them. The effects of the imaging duty cycle and frame rate on the accuracy of dosimetric verification have been studied. A...
BACKGROUND We sought to determine the intra- and inter-radiation therapist reproducibility of a previously established matching technique for daily verification and correction of isocenter position relative to intraprostatic fiducial markers (FM). MATERIALS AND METHODS With the patient in the treatment position, anterior-posterior and left lateral electronic images are acquired on an amorphou...
Introduction: Tumor control and treatment quality depend on accuracy of delivered dose. Various methods have been studied for treatment dosimetry verification. Among these methods, the use of electronic portal imaging device (EPID) is highly considered. Many efforts are underway to improve the results of this context. Materials and Methods: In this study, ...
a-Si Electronic Portal Imaging Device (EPID) is an important tool to verify the location of the radiation therapy beam with respect to the patient anatomy. But, Electronic Portal Images (EPI) suffer from low contrast. In order to have better in-treatment images to extract relevant features of the anatomy, image processing tools need to be integrated in the Radiology systems. The goal of this re...
A method of reconstructing three-dimensional, in vivo dose distributions delivered by intensity-modulated radiotherapy (IMRT) is presented. A proof-of-principle experiment is described where an inverse-planned IMRT treatment is delivered to an anthropomorphic phantom. The exact position of the phantom at the time of treatment is measured by acquiring megavoltage CT data with the treatment beam ...
Telah dilakukan penelitian mengenai verifikasi pergesesaran geometri pada pesawat Linear Accelerator (Linac) tipe Clinax CX menggunakan Electronic Portal Imaging Device (EPID). Verifikasi 10 data rekam medis pasien kanker nasofaring di Instalasi Radioterapi Rumah Sakit Universitas Andalas. Proses diawali dengan perencanaan Treatment Planning System (TPS) Software Eclipse dilanjutkan penyinaran ...