نتایج جستجو برای: fe 2 selective electrode

تعداد نتایج: 2776642  

Journal: :Environmental science & technology 2013
Peng Liao Songhu Yuan Mingjie Chen Man Tong Wenjing Xie Peng Zhang

A novel Pd-based electro-Fenton (E-Fenton) process has recently been developed to transform organic contaminants in groundwater. However, it only produces H2O2 and requires addition of Fe(2+). In this study, an innovative approach is developed to effectively regulate the generation of Fe(2+) from an iron cathode in a three-electrode system in addition to H2O2 production. The Fe(2+) is then used...

Journal: :journal of physical & theoretical chemistry 2011
m. kia a. islamnezhad sh. shariati

in order to preparing strontium ion selective electrode 6-(4- nitropheny1)-2-pheny14, 4- dipropy1-3, 5-diaza-bicyclo [3, 1, 0] hex-2-ene (npdbh) was used as an ionophore. this electrode responds to sr (ii)ion with a sensitivity of 28.2 ± 0.5 mv/decade over the range 1.0 x 10-6 to 1.0 mat ph 3.0-10.0. thelimit of detection was 2.4 x 10-7 m. the influences of membrane composition, the ph of the t...

Journal: :archives of hygiene sciences 0
afshin takdastan environmental technologies research center, ahvaz jundishapur university of medical sciences, ahvaz, iran majid farhadi ahvaz jundishapur university of medical science jila salari ahvaz jundishapur university of medical science neda kayedi ahvaz jundishapur university of medical science bayram hashemzadeh urmia university of medical sciences mohammad javad mohammadi abadan school of medical sciences, abadan, iran

background & aims of the study: detergent and phosphate are one of the main and vital threats (eutrophication phenomenon and production of synthetic foam) for the source of drinking water, agriculture and industrial uses in the ahvaz, iran that threaten human health. the aim of this study is the evaluation of the efficiency of the electrocoagulation (ec) process in the removal of detergent and ...

Journal: :journal of physical & theoretical chemistry 2012
m. h. fekri m. darvishpour

a pvc membrane ni(ii) ion selective electrode has been constructed using (1e,2e)-bis(2-aminophenyl)n'1,n'2-dihydroxyethanebis as membrane carrier. the electrode exhibited a goodpotentiometric response for ni(ii) over a wide concentration range 1.0×10-4 to 1.0×10-1m with aslope of 29.4±0.5 mv/decade a and a working ph range of 6.5-9.0. it had a fast response time of≤20s. the best performance was...

Journal: :journal of physical and theoretical chemistry 0
m. h. fekri - m. darvishpour -

a pvc membrane ni(ii) ion selective electrode has been constructed using (1e,2e)-bis(2-aminophenyl)n'1,n'2-dihydroxyethanebis as membrane carrier. the electrode exhibited a goodpotentiometric response for ni(ii) over a wide concentration range 1.0×10-4 to 1.0×10-1m with aslope of 29.4±0.5 mv/decade a and a working ph range of 6.5-9.0. it had a fast response time of≤20s. the best perfo...

Forogh Adhami Leila Hajiaghababaei Saeid Takalou

N-(2H-[1,2,4]thiadiazolo[2,3-a]pyridine-2-ylidene)benzamide was used as a selective sensing material in the PVC membrane to construction of a new chromium ion selective electrode. This liquid membrane electrode worked well with a Nernstian response of 19.7 ±0.4 mV decade-1 of Cr(III) in a wide dynamic concentration range of 8.0× 10-6-1.0×10-1 M. The electrode had relatively short response time ...

An ultrasensitive electrochemical immunosensor for the detection of tumor marker human chorionic gonadotropin (hCG) was developed with a limit of detection as low as 2 pg mL-1 in phosphate buffer. The Platinum nanoparticles (PtNPs) were electrodeposited to modify the gold surface and to increase enlarging the electrochemically active sites, resulting in the facilitation of electron exchange. Cy...

Journal: :analytical and bioanalytical chemistry research 2014
a. shokrollahi a. abbaspourb a. naghashian haghighia a. h. kianfar

a new al(iii) selective membrane based on 5-bromo(salicylidene-2-amino thiophenol) as a neutral carrier in a poly(vinyl chloride) (pvc) matrix is coated on platinum wire to determine trace amounts of al(iii) ion in various samples. the sensor exhibits a good response for al(iii) ion over a wide concentration range of 5.20 × 10-7 to 1.00 × 10-2 m  with nernstian slope of 19.64 ± 0.15 mv decade-1...

2007
M. Muzibur Rahman Il C. Jeon

Redox reaction [Fe(CN)6] 3– / [Fe(CN)6] 4– has been studied with a Single-Walled Carbon Nanotube (SWCNT)-coated Glassy Carbon Electrode (GCE), SWCNT-coated Gold Electrode (GE) and a lab-made SWCNT-TPLF (SWCNT-Thin-Paper-Like-Film) Electrode. The SWCNT-modified electrode has shown a well-defined redox peak compared to bare electrodes. Cyclic voltammetry was used in 50.0 × 10–3 M aqueous solution...

نمودار تعداد نتایج جستجو در هر سال

با کلیک روی نمودار نتایج را به سال انتشار فیلتر کنید