نتایج جستجو برای: femoral stem
تعداد نتایج: 316244 فیلتر نتایج به سال:
PURPOSE The purpose of this study was to evaluate the clinical and radiological results of total hip arthroplasty using a proximal modular femoral stem in patients who had secondary coxarthrosis associated with a dysplastic hip. MATERIALS AND METHODS Forty-two patients (45 hips) with secondary coxarthrosis were evaluated after undergoing primary total hip arthroplasty using an S-ROM proximal ...
Femoral revision after cemented total hip replacement (THR) might include technical difficulties, following essential cement removal, which might lead to further loss of bone and consequently inadequate fixation of the subsequent revision stem. Femoral impaction allografting has been widely used in revision surgery for the acetabulum, and subsequently for the femur. In combination with a primar...
PURPOSE We evaluated the results of more than 10 years of follow-up of total hip arthroplasty using a second-generation cementless femoral prosthesis with a collar and straight distal fixation channels. MATERIALS AND METHODS One hundred five patients (129 hips) who underwent surgery between 1991 and 1996 for primary total hip arthroplasty using cementless straight distal fluted femoral stems ...
PURPOSE To evaluate hip parameters such as vertical centre of rotation (VCR), horizontal centre of rotation (HCR), femoral offset, and leg length after total hip arthroplasty (THA) using the Nanos short-stem prosthesis. METHODS Medical records of 73 men and 74 women aged 25 to 92 (mean, 63) years who underwent THA using the Nanos short-stem prosthesis by a single surgeon were reviewed. Prior ...
PURPOSE To evaluate the discrepancy between the anatomical axis of the distal femur of Japanese patients and the stem position of 5 types of femoral components. METHODS Lateral radiographs of 12 men and 88 women aged 31 to 83 (mean, 59) years with rheumatoid arthritis were evaluated. The discrepancy between the anatomical axis of the distal femur and the stem position of 5 types of femoral co...
We used a trochanteric slide osteotomy (TSO) in 94 consecutive revision total hip arthroplasties (90 with replacement of both the cup and stem). This technique proved to be adequate for removing the components, with few complications (two minor fractures), and for implanting acetabular allografts (18%) and reinforcement devices (23%). Trochanteric union was obtained in most patients (96%), even...
BACKGROUND Hemiarthroplasty is a common operation to treat femoral neck fracture in elderly patients. The choice of whether to use cemented stem or cementless stem in hemiarthroplasty has been controversial in clinical practice. However, recent trends regarding stem choice in South Korea are not known or documented. In this study, we assessed the trends of stem fixation in hemiarthroplasty for ...
Knee revision using constrained implants is associated with greater stresses on the implant and interface surfaces. The present report describes a case of failure of the screw coupling between the stem and the femoral component. The cause of the failure is surmised with outline of the treatment in this case with extensive femoral bone loss. Revision implant stability was augmented with the use ...
Thirty-five total hip arthroplasties (33 patients) were performed in cases of Crowe grade III or IV hip dysplasia using subtrochanteric shortening osteotomy with two kinds of femoral stem: monoblock and modular type. All acetabular components were used with a cementless cup. The average patient age was 47.8 years, and the average follow-up time was 5.1 years. Acetabular reconstruction was perfo...
BACKGROUND We evaluated the mid-term results of previously cemented hip arthroplasties revised with uncemented modular femoral components. METHODS The study included 40 patients (36 females (90 %) and 4 males (10 %), mean age 67.6 years, range 39-87 years) who underwent revision of a previously cemented hip prosthesis with an uncemented modular femoral stem between 2005 and 2009. The indicati...
نمودار تعداد نتایج جستجو در هر سال
با کلیک روی نمودار نتایج را به سال انتشار فیلتر کنید