Navigation of the cup in total hip arthroplasty is well analyzed and shows accurate results, reducing cup outliers of Lewinnek's "safe zone." With regard to the combined anteversion of cup and stem, however, a "new" safe zone with a range of 25° to 50° has been published. The aim of this study was to analyze total anteversion (cup and stem) by postoperative 3D computed tomography in isolated cu...
Progressive retroversion of a cemented stem is predictive of early loosening and failure. We assessed the relationship between direct post-operative stem anteversion, measured with CT, and the resulting rotational stability, measured with repeated radiostereometric analysis over ten years. The study comprised 60 cemented total hip replacements using one of two types of matt collared stem with a...
BACKGROUND We evaluated the mid-term results of previously cemented hip arthroplasties revised with uncemented modular femoral components. METHODS The study included 40 patients (36 females (90 %) and 4 males (10 %), mean age 67.6 years, range 39-87 years) who underwent revision of a previously cemented hip prosthesis with an uncemented modular femoral stem between 2005 and 2009. The indicati...
Abstract Background The femoral component anteversion during surgery is traditionally assessed by a visual assessment of the surgeon and has proven to be imprecise. We sought determine accuracy digital protractor spirit level measure stem cementless THA. Methods A prospective study was conducted among 107 patients (114 hips) who underwent primary THA via posterolateral approach. pipe with attac...
OBJECTIVE To determine the extent to which select lower extremity alignment characteristics of the pelvis, hip, knee, and foot are related to the Q angle. DESIGN Descriptive cohort study design. SETTING Applied Neuromechanics Research Laboratory. PARTICIPANTS Two hundred eighteen participants (102 males, 116 females). ASSESSMENT OF RISK FACTORS Eight clinical measures of static alignmen...
BACKGROUND AND PURPOSE The clinical results of THR may be improved by correct femoral torsion. We evaluated the stem position by postoperative CT examination in 60 patients. METHODS 60 patients requiring total hip arthroplasty were prospectively enrolled in this study. Minimally invasive THR was performed (anterior approach) in a lateral decubitus position and each patient underwent a postope...
Background: Toe in gait may be due to metatarsus adductus, increase tibia torsion and femoral anteversion. It is controversial that it influences on standing stability or not. Therefore, the aim of this study was evaluate effects toe gait, head anteversion, stability. Method: 11 subjects with anteversion were recruited study. There also a control group matched group. A Kistler force plate used ...
There is much debate about the nature and extent of deformities in the proximal femur in children with cerebral palsy. Most authorities accept that increased femoral anteversion is common, but its incidence, severity and clinical significance are less clear. Coxa valga is more controversial and many authorities state that it is a radiological artefact rather than a true deformity. We measured f...
Progressive retroversion of a cemented stem is predictive of early loosening and failure. We assessed the relationship between direct post-operative stem anteversion, measured with CT, and the resulting rotational stability, measured with repeated radiostereometric analysis over ten years. The study comprised 60 cemented total hip replacements using one of two types of matt collared stem with a...