Das/Cheng/Pai/AAPM//2002 Historical Perspective 1826 Joseph Niepce First Photograph 1836 J. M. Daguerre Concept of developer 1889 Eastman Kodak Cellulose nitrate base for emulsion 1890 Hurter &Driffield Defined the term optical density 1895 Roentgen First Radiograph 1896 Carl Schlussner First glass plate for radiography 1913 Kodak Film on Cellulose nitrate base 1918 Kodak Double emulsion film 1...
An extensive study was undertaken to Investigate on the overall film badge service performance with which occupational radiation, exposures are reported In Iran, The study involved the analysis of film badges exposed to x-and gamma rays and beta particles. For test exposures, x-rays between 60 and 140 KVPCo-60 gamma radiation and Sr-90 beta particles were used. The actual delivered dose equival...
PURPOSE To evaluate the uncertainties and characteristics of radiochromic film-based dosimetry system using the EBT3 model Gafchromic(®) film in therapy photon, electron and proton beams. MATERIAL AND METHODS EBT3 films were read using an EPSON Expression 10000XL/PRO scanner. They were irradiated in five beams, an Elekta SL25 6 MV and 18 MV photon beam, an IBA 100 MeV 5 × 5 cm(2) proton beam ...
Introduction: The presence of heterogeneities such as air-filled cavities in the head and neck treatment fields region, may result in potential dosimetric disagreement because the losses of charged particle equilibrium. Most of treatments planning systems are not able to predict dose distribution of inhomogeneities region accurately. Therefore, dose calculation algorithms need to...
Photon beam dosimetry using Kodak extended dose range (EDR2) radiographic film can provide accurate and high spatial resolution information especially for areas such as IMRT dosimetry where a higher dose level (100-400 cGy) is often required to be delivered for verification. For such dosimetry checks, it may sometimes be useful to place the film in a tank filled with water during irradiation. T...
Radiochromic film is tested for its broad-band response to ultraviolet (UV) B (290-320 nm) and A (320 nm400 nm), visible and infrared radiation produced by a solar simulator and examined for dosimetry in ultraviolet radiation. Results show that MD-55-2 radiochromic film in solar and fluorescent light sources responds almost exclusively to broad-band UVA radiation with negligible colouration fro...
introduction: the conventional methods of dosimetry are not capable of dosimetry in such a small volume of less than one cubic millimeter. although the polymer gel dosimetry method based on magnetic resonance imaging (mri) could achieve three dimensional dosimetry with high resolution, a spatial resolution evaluation based on gel dose modulation transfer function has not been investigated yet. ...
The whole-body and hand radiation doses to our technical staff were retrospectively compared for three distinct 4-mo periods when either 201TI or 99mTc-sestamibi were exclusively used for stress myocardial perfusion imaging. During the initial 4-mo period when 99mTc-sestamibi replaced 201TI, the mean whole-body film badge readings increased from 100 to 450 microSv/mo (p < 0.001) for nuclear med...