نتایج جستجو برای: gafchromic film stereotactic radiotherapy

تعداد نتایج: 159884  

A.H. Barati, H.A. Nedaie, M. Afkhami, M. Yarahmadi, M.H. Zahmatkesh, W. Parwaie,

Background: Accurate small radiation field dosimetry is essential in modern radiotherapy techniques such as stereotactic radiosurgery (SRS) and intensity modulated radiotherapy (IMRT). Precise measurement of dosimetric parameters such as beam profile, percentage depth doses and output factor of these beams are complicated due to the electron disequilibrium and the steep dose gradients. In the p...

Journal: :Medical physics 2007
Sujatha Pai Indra J Das James F Dempsey Kwok L Lam Thomas J Losasso Arthur J Olch Jatinder R Palta Lawrence E Reinstein Dan Ritt Ellen E Wilcox

TG-69 is a task group report of the AAPM on the use of radiographic film for dosimetry. Radiographic films have been used for radiation dosimetry since the discovery of x-rays and have become an integral part of dose verification for both routine quality assurance and for complex treatments such as soft wedges (dynamic and virtual), intensity modulated radiation therapy (IMRT), image guided rad...

Journal: :Bulletin du cancer 2013
Ronan Tanguy Philippe Métellus Françoise Mornex Jean-Jacques Mazeron

Brain metastases management is still controversial even though many trials are trying to define the respective roles of neurosurgery, whole-brain radiotherapy, single-dose stereotactic radiotherapy and fractionated stereotactic radiotherapy. In this article, we review data from trials that examine the role of radiosurgery and fractionated stereotactic radiotherapy in the management of brain met...

Journal: :Applied radiation and isotopes : including data, instrumentation and methods for use in agriculture, industry and medicine 2006
Tsang Cheung Martin J Butson Peter K N Yu

The EBT Gafchromic radiochromic film is a relatively new product designed specifically for dosimetry in radiation therapy. Due to the weak dependence of its response on the photon energy (variations are below 10% in the 50 kVp-10 MVp range), the film is ideal for dosimetry when the photon energy spectrum may be changing or unknown. In order to convert a map of optical densities into a map of ab...

Objective(s): Radiotherapy is one of the most effective modalities of cancer therapy, but clinical responses of individual patients varies considerably. To enhance treatment efficiency it is essential to implement an individual-based treatment. The aim of present study was to identify the mechanism of intrinsic apoptosis pathway on radiosensitivity and normal tissue complications caused by the ...

2007
George Ciangaru James N. Yang Patrick J. Oliver Martin Bues Mengping Zhu Fumio Nakagawa Hitoshi Chiba Shin Nakamura Hirofumi Yoshino Mosumi Umezawa Alfred R. Smith

We present a technique--based on the Lutz, Winston, and Maleki test used in stereotactic linear accelerator radiosurgery--for verifying whether proton beams are being delivered within the required spatial coincidence with the gantry mechanical isocenter. Our procedure uses a proton beam that is collimated by a circular aperture at its central axis and is then intercepted by a small steel sphere...

Journal: :Japanese journal of clinical oncology 2011
Shunsuke Onodera Hidefumi Aoyama Norio Katoh Hiroshi Taguchi Kouichi Yasuda Daisuke Yoshida Ken Surtherland Ryusuke Suzuki Masayori Ishikawa Bengua Gerard Shunsuke Terasaka Hiroki Shirato

OBJECTIVE To investigate the outcome of linac-based fractionated stereotactic radiotherapy over the last 10 years for intracranial skull base benign meningiomas in patients who were inoperable, who had residual tumors with some components of high mitotic index after surgery and who experienced relapse of the tumor. METHODS Twenty-seven patients with intracranial skull base benign meningiomas ...

Journal: :The Medical journal of Malaysia 2011
I Zamzuri I Badrisyah G I Rahman H K Pal M Muzaimi A M Jafri M War A M Shafie N I Nik Ruzman B M Biswal Z Ahmad

BACKGROUND Stereotactic radiosurgery uses a single fraction high dose radiation while stereotactic radiotherapy uses multifractionated lower dose focused radiation. MATERIALS AND METHODS Radiosurgery used rigid CRW head frame while stereotactic radiotherapy utilized GTC or HNL relocatable frames. Stereotactic planning and radiation involved Radionics X-plan and LINAC system. RESULTS Since D...

Journal: :The Lancet. Oncology 2014
Gert De Meerleer Vincent Khoo Bernard Escudier Steven Joniau Alberto Bossi Piet Ost Alberto Briganti Valérie Fonteyne Marco Van Vulpen Nicolaas Lumen Martin Spahn Marc Mareel

Renal-cell carcinoma is considered to be a radioresistant tumour, but this notion might be wrong. If given in a few (even single) fractions, but at a high fraction dose, stereotactic body radiotherapy becomes increasingly important in the management of renal-cell carcinoma, both in primary settings and in treatment of oligometastatic disease. There is an established biological rationale for the...

نمودار تعداد نتایج جستجو در هر سال

با کلیک روی نمودار نتایج را به سال انتشار فیلتر کنید