نتایج جستجو برای: gelatin phantom

تعداد نتایج: 26329  

Journal: :Medical physics 2011
Elijah E W Van Houten D vR Viviers M D J McGarry P R Perriñez I I Perreard J B Weaver K D Paulsen

PURPOSE Recently, the attenuating behavior of soft tissue has been addressed in magnetic resonance elastography by the inclusion of a damping mechanism in the methods used to reconstruct the resulting mechanical property image. To date, this mechanism has been based on a viscoelastic model for material behavior. Rayleigh, or proportional, damping provides a more generalized model for elastic en...

2016
Siang-Wen Lan Min-Hang Weng Ru-Yuan Yang Shoou-Jinn Chang Yaoh-Sien Chung Tsung-Chih Yu Chun-Sen Wu

In this paper, the oil-in-gelatin based tissue-mimicking materials (TMMs) doped with carbon based materials including carbon nanotube, graphene ink or lignin were prepared. The volume percent for gelatin based mixtures and oil based mixtures were both around 50%, and the doping amounts were 2 wt %, 4 wt %, and 6 wt %. The effect of doping material and amount on the microwave dielectric properti...

Journal: :IEEE-ASME Transactions on Mechatronics 2023

In this article, we present a new method to control the thermal stimulation of skin during photorejuvenation procedure. The proposed can precisely administer dose while controlling tissue's temperature under safe limit. For that, model-based treatment controller is developed and evaluated on 3-D biophysics-based numerical model skin. A hardware implementation experimentally tested gelatin-based...

Journal: :iranian journal of radiation research 0
s. senthilkumar department of radiotherapy, madurai medical college and govt. rajaji hospital, maduari-625 020, india

background: the purpose of this study is to fabricate inexpensive in-house low cost homogeneous and heterogeneous human equivalent thorax phantom and assess the dose accuracy of the treatment planning systems (tps) calculated values for different lung treatment dosimetery. it is compared with thermoluminescent dosimeter (tld) measurement. materials and methods: homogeneous and heterogeneous tho...

Journal: :iranian journal of radiation research 0
j.w. hong department of radiation oncology, seoul national university bundang hospital, republic of korea h.k. lee department of computer science and engineering, soonchunhyang university, republic of korea j.h. cho department of international radiological science, hallym university of graduate studies, republic of korea

background: this study assessed the clinical usefulness of the solid phantom, which may compensate for the disadvantages of the water phantom, by comparing the radiological doses between the two depending on their depths. materials and methods: the experimental equipment used was a linear accelerator for medical use, water phantom, solid phantom, farmer type ion chamber and electrometer. the di...

Journal: :Nanoscale 2011
Weiyang Li Xin Cai Chulhong Kim Guorong Sun Yu Zhang Rui Deng Miaoxin Yang Jingyi Chen Samuel Achilefu Lihong V Wang Younan Xia

This paper describes the use of Au nanocages covered with smart, thermally-responsive polymers for controlled release with high-intensity focused ultrasound (HIFU). HIFU is a highly precise medical procedure that uses focused ultrasound to heat and destroy pathogenic tissue rapidly and locally in a non-invasive or minimally invasive manner. The released dosage could be remotely controlled by ma...

2007
Michael R Rossi Yoed Rabin

As a part of an ongoing effort to develop computerized planning tools for cryosurgery, an experimental study has been conducted to verify a recently developed numerical technique for bioheat transfer simulations. Experiments were performed on gelatin solution as a phantom material, using proprietary liquid-nitrogen cryoprobes. Urethral warming was simulated with the application of a cryoheater,...

Journal: :Journal of the Optical Society of America. A, Optics, image science, and vision 2014
Calvin B Shaw Phaneendra K Yalavarthy

The sparse estimation methods that utilize the ℓp-norm, with p being between 0 and 1, have shown better utility in providing optimal solutions to the inverse problem in diffuse optical tomography. These ℓp-norm-based regularizations make the optimization function nonconvex, and algorithms that implement ℓp-norm minimization utilize approximations to the original ℓp-norm function. In this work, ...

نمودار تعداد نتایج جستجو در هر سال

با کلیک روی نمودار نتایج را به سال انتشار فیلتر کنید