نتایج جستجو برای: head scatter factor sc medical accelerator mini phantom

تعداد نتایج: 1631298  

Fateme Shahedi, Hossein Akbari Mahdi Jamali Mahdi Mommen nezhad shahrokh Nasseri,

Introduction: The success of radiotherapy cancer treatment delivery depends on the accuracy of patient positioning for each treatment session. A number of kilovoltage x-ray volumetric imaging modalities with an additional source and detector have been developed to allow patient set-up verification based on the internal anatomy, but a significant portion of medical linacs are on...

2009
Jinsong Ouyang Xuping Zhu Cathryn M. Trott Georges El Fakhri

Simultaneous rest Tc-Sestamibi / I-BMIPP cardiac SPECT imaging has the potential to replace current clinical Tc-Sestamibi rest/stress imaging and therefore has great potential in the case of patients with chest pain presenting to the emergency department. Separation of images of these two radionuclides is difficult, however, because their emission energies are close. The authors previously deve...

2011
Angelica Svalkvist Gustaf Ullman Markus Håkansson David Dance Michael Sandborg Gudrun Alm Carlsson Magnus Båth

The primary aim of the present work was to analyze the effects of varying scatter-to-primary ratios on the appearance of simulated nodules in chest tomosynthesis section images. Monte Carlo simulations of the chest tomosynthesis system GE Definium 8000 VolumeRAD (GE Healthcare, Chalfont St. Giles, UK) were used to investigate the variation of scatter-to-primary ratios between different angular ...

Journal: :journal of biomedical physics and engineering 0
n mohammadi s h miri-hakimabad l rafat-motavalli

background: high-energy linear accelerator (linac) is a valuable tool and the most commonly device for external beam radiation treatments in cancer patients. in the linac head, high-energy photons with energies above the threshold of interaction produce photoneutrons. these photoneutrons deliver the extra dose to the patients in the planning treatment and increase the risk of secondary cancer. ...

Journal: :Technology in cancer research & treatment 2002
C A MacDonald W M Gibson W W Peppler

Polycapillary x-ray optics provide an innovative new way to control x-ray beams. Placing these optics after the object to be imaged provides very efficient rejection of Compton scatter, while allowing image magnification without loss of resolution, image demagnification, or image shaping to match with digital detectors. Measured scatter rejection optics had primary transmissions greater than 50...

Journal: :iranian journal of medical physics 0
afshin akbarzadeh ph.d. student, department of medical physics and biomedical engineering and research center for science and technology in medicine, tehran university of medical sciences, tehran, iran mohammad rreza ay assistant professor in biomedical engineering, biomedical systems & medical physics dept., tehran university of medical sciences & research center for science and technology in medicine, tehran, iran. hossein ghadiri ph.d. student, department of medical physics and biomedical engineering and research center for science and technology in medicine, tehran university of medical sciences, tehran, iran saied sarkar associate professor in biomedical engineering, biomedical systems & medical physics dept., tehran university of medical sciences & research center for science and technology in medicine, tehran, iran.

introduction: one of the most important parameters in x-ray ct imaging is the noise induced by detected scattered radiation. the detected scattered radiation is completely dependent on the scanner geometry as well as size, shape and material of the scanned object. the magnitude and spatial distribution of the scattered radiation in x-ray ct should be quantified for development of robust scatter...

Journal: :Medical physics 2009
Lei Zhu Jing Wang Lei Xing

Scatter correction is crucial to the quality of reconstructed images in x-ray cone-beam computed tomography (CBCT). Most of existing scatter correction methods assume smooth scatter distributions. The high-frequency scatter noise remains in the projection images even after a perfect scatter correction. In this paper, using a clinical CBCT system and a measurement-based scatter correction, the a...

Journal: :iranian journal of radiation research 0
k.n. esnaashari department of medical physics tehran university of medical sciences, tehran, iran m. allahverdi department of medical physics tehran university of medical sciences, tehran, iran h. gharaati department of medical physics tehran university of medical sciences, tehran, iran m. shahriari department of medical radiation, shahid beheshti university, tehran, iran

background: stereotactic radiosurgery is an important clinical tool for the treatment of small lesions in the brain, including benign conditions, malignant and localized metastatic tumors. a dosimetry study was performed for elekta ‘synergy s ’ as a dedicated stereotactic radiosurgery unit, capable of generating circular radiation fields with diameters of 1-5 cm at isocentre using the beam/egs4...

Journal: :Biointerface Research in Applied Chemistry 2021

A digital phantom was created from a CT scan of patient’s head and employed together with GATE 8.2 Monte Carlo modeling linear accelerator nominal 6 MV energy to simulate an irradiation geometry for typical tumor volume centrally within the brain region. Although simplistic in arrangement, this setup considered appropriate demonstrate dose enhancements that may be expected megavoltage external ...

Journal: :iranian journal of radiation research 0
j.w. hong department of radiation oncology, seoul national university bundang hospital, republic of korea h.k. lee department of computer science and engineering, soonchunhyang university, republic of korea j.h. cho department of international radiological science, hallym university of graduate studies, republic of korea

background: this study assessed the clinical usefulness of the solid phantom, which may compensate for the disadvantages of the water phantom, by comparing the radiological doses between the two depending on their depths. materials and methods: the experimental equipment used was a linear accelerator for medical use, water phantom, solid phantom, farmer type ion chamber and electrometer. the di...

نمودار تعداد نتایج جستجو در هر سال

با کلیک روی نمودار نتایج را به سال انتشار فیلتر کنید