نتایج جستجو برای: holter monitoring
تعداد نتایج: 300192 فیلتر نتایج به سال:
BACKGROUND Detection of intermittent atrial fibrillation (AF) is done using a 24-h Holter. Holter recordings are powerful but lack the comfort and have limited recording times resulting in under diagnosing of intermittent AF. OBJECTIVE Within this work we evaluated and compared a novel miniaturized three-channel ECG monitoring patch versus a 24-h Holter system. METHODS Both patients with a ...
Background Cardiac arrhythmias, including atrial fibrillation (AF), are a common cause for seeking medical care. AF has many causes; where valvular disease, hypertension, heart failure and diabetes mellitus are among the most common ones. The golden standard for arrhythmia monitoring is a 24or 48-hours Holter monitor. The aim with this paper was to compare the Holter monitor with chest strap EC...
A 56 year-old woman with a transplanted heart, with arterial hypertension and chronic pulmonary obstructive disease, was hospitalised because of palpitations, dyspnea, chest pain and oedema. After cyclosporine treatment she was diagnosed with renal failure, which was treated by hemodialysis. Heart rate (HR) at admission was 100, mean HR in 24-hour Holter monitoring was 106 bpm. Ivabradine was a...
BACKGROUND AND PURPOSE Holter monitoring for the detection of paroxysmal atrial fibrillation (PAF) is a routine procedure after cerebral ischemic events, although its value is unknown. The aim of this study was to evaluate the incidence of PAF and its impact on drug treatment modifications in this population. METHODS Retrospective evaluation of all Holter ECGs in patients with cerebral ischem...
AIMS Holter monitoring (HM) has been established as one of the most effective noninvasive clinical tools in the diagnosis, assessment and risk stratification of cardiac patients. However, studies in the pediatric age group are limited. The present work aims at determining the value of HM in the diagnosis and management of children. SETTINGS AND DESIGN Retrospective study conducted at a tertia...
The sudden death of a diabetic patient (NIDDM) during Holter monitoring is described. The patient was a 64-yr-old male with an 11-yr history of diabetic nephropathy, retinopathy, autonomic nervous dysfunction, and old myocardial infarction. In spite of all these complications, he remained asymptomatic and eventually resumed his normal activities, including a daily 1-h walk, until his sudden dea...
BACKGROUND AND PURPOSE A significant number of patients with cryptogenic stroke suffer from intermittent atrial fibrillation (iAF) which was not detected during the standard diagnostic procedures. We investigated whether implantation of an insertable cardiac monitor (ICM) is feasible in patients with cryptogenic stroke, and compared the iAF detection rate of the ICM with 7-day Holter monitoring...
نمودار تعداد نتایج جستجو در هر سال
با کلیک روی نمودار نتایج را به سال انتشار فیلتر کنید