Journal: :Medical physics 2010
Sedat Ozer Deanna L Langer Xin Liu Masoom A Haider Theodorus H van der Kwast Andrew J Evans Yongyi Yang Miles N Wernick Imam S Yetik

PURPOSE Magnetic resonance imaging (MRI) has been proposed as a promising alternative to transrectal ultrasound for the detection and localization of prostate cancer and fusing the information from multispectral MR images is currently an active research area. In this study, the goal is to develop automated methods that combine the pharmacokinetic parameters derived from dynamic contrast enhance...

Abbas Haghparast Golestan Karami Mahdi Momen Nezhad Peyman Hejazi, Shahrokh Naseri Zahra Hozhabri

Introduction In computed tomography (CT) technology, an optimal radiation dose can be achieved via changing radiation parameters such as mA, pitch factor, rotation time and tube voltage (kVp) for diagnostic images. Materials and Methods In this study, the brain, abdomen, and thorax scaning was performed using Toshiba 16-slice scannerand standard AAPM and CTDI phantoms. AAPM phantom was used for...

H. Pourbeigi, M.H. Zahmatkesh, Sh. Akhlaghpoor,

Background: Since 1984 MRI gel dosimetry has been introduced as a potential technique for 3D dosimetry. Most of the studies have measured R1 (1/T1) or R2 (1/T2) properties of the gel depending on the gel type. We have studied image intensity change in the Fricke gel by different MRI protocols. Materials and Methods: Gel Dosimeters contain 0.4 mM ferrous sulphate, 1 mM NaCl, 50 mM H2SO4 and 1% b...

پایان نامه :وزارت علوم، تحقیقات و فناوری - دانشگاه گیلان - دانشکده فنی و مهندسی 1390

magnetic resonance imaging (mri) is a notable medical imaging technique that makes of phenomenon of nuclear magnetic resonance. because of the resolution and the technology being harmless, mri has considered as the most desirable imaging technique in clinical applications. the visual quality of mri plays an important role in accuracy of medical delineations that can be seriously degraded by exi...

پایان نامه :دانشگاه تربیت معلم - سبزوار - دانشکده برق و کامپیوتر 1392

در حال حاضر چندین روش برای اندازه گیری چربی زیرپوستی بدن در حوزه های بالینی وجود دارد ، مانند : magnetic resonance imaging(mri)، (computer tomography(ct، ultrasound imaging(us) ، dual energy x-ray absorptiometry(dexa). این روش ها بطور وسیعی در حوزه های بالینی به عنوان وسایل دقیق و مفید ، مورد استفاده قرار می گیرند. به هر حال این روش ها محدودیت های زیادی مانند هزینه بالا و یا خطر تابش اشعه را دا...

Journal: :iranian journal of radiation research 0
sh. akhlaghpoor dr. sh. akhlaghpoor, novin medical radiation institute, p.o.box: 14665/599, tehran, iran; fax:(98) 218086782 m.h. zahmatkesh h. pourbeigi

background: since 1984 mri gel dosimetry has been introduced as a potential technique for 3d dosimetry. most of the studies have measured r1 (1/t1) or r2 (1/t2) properties of the gel depending on the gel type. we have studied image intensity change in the fricke gel by different mri protocols. materials and methods: gel dosimeters contain 0.4 mm ferrous sulphate, 1 mm nacl, 50 mm h2so4 and 1% b...

Introduction: Glioma is the most common primary malignancy of cerebral neoplasms in adults, which in spite of therapeutic significant efforts, has a very poor prognosis. The current standard treatment of these patients generally includes surgery and radiotherapy or concurrent chemoradiotherapy with 6 courses of adjuvant use of temozolomide tabs. During these years, the nervous...

Background and Aim: Diagnosing the status of the posterior ligament complex (PLC) plays an essential role in the management of patients with thoracolumbar fractures. In this study, due to the inefficiency of existing imaging modalities in the accurate detection of PLC damage, we investigated the relevance of some imaging parameters to specific guidelines for rapid PLC injury detection. Methods...

2007
H. Kolanoski

Using the ARGUS detector at the e+e storage ring DORIS II, we have measured the Michel parameters , , and for ! l  decays in -pair events produced at center of mass energies in the region of the resonances. Using ! as spin analyzing tags, we nd e = 0:68 0:04 0:08, e = 1:12 0:20 0:09, e = 0:57 0:14 0:07, = 0:69 0:06 0:08, = 1:25 0:27 0:14 and = 0:72 0:18 0:10. In addition, we report the combine...

1999
Rahul Mukerjee

In the presence of nuisance parameters, we derive an explicit higher order asymptotic formula to compare the expected lengths of conndence intervals given by likelihood ratio statistics arising from the usual proole likelihood and various adjustments thereof. Highest posterior density regions, with approximate frequentist validity, are also included in the study.