نتایج جستجو برای: implant interface

تعداد نتایج: 250662  

Journal: :Computer methods in biomechanics and biomedical engineering 2017
Valérie Malfroy Camine Alexandre Terrier Dominique P Pioletti

Micromotion-induced interstitial fluid flow at the bone-implant interface has been proposed to play an important role in aseptic loosening of cementless implants. High fluid velocities are thought to promote aseptic loosening through activation of osteoclasts, shear stress induced control of mesenchymal stem cells differentiation, or transport of molecules. In this study, our objectives were to...

Journal: :The Journal of bone and joint surgery. British volume 2000
R A Brooks J R Sharpe J A Wimhurst B J Myer E N Dawes N Rushton

We used a rat model in vivo to study the effects of the concentration of polyethylene particles on the bone-implant interface around stable implants in the proximal tibia. Intra-articular injections of 10(4), 10(6) or 10(8) high-density polyethylene (HDPE) particles per joint were given 8, 10 and 12 weeks after surgery. The animals were killed after 14 and 26 weeks and the response at the inter...

2017
Hsiang-Ho Chen Wei-Yi Lai Tze-Jian Chee Ya-Hui Chan Sheng-Wei Feng

The aim of this study was to monitor the changes of viscoelastic properties at bone-implant interface via resonance frequency analysis (RFA) and the Periotest device during the healing process in an experimental rabbit model. Twenty-four dental implants were inserted into the femoral condyles of rabbits. The animals were sacrificed immediately after implant installation or on day 14, 28, or 56 ...

2017
Michael Gasik

One of the greatest challenges in the development of new medical products and devices remains in providing maximal patient safety, efficacy and suitability for the purpose. A 'good quality' of the tissue-implant interface is one of the most critical factors for the success of the implant integration. In this paper this challenge is being discussed from the point of view of basic stimuli combina...

Journal: :BMC Musculoskeletal Disorders 2007
Ola LA Harrysson Yasser A Hosni Jamal F Nayfeh

BACKGROUND Conventional knee and hip implant systems have been in use for many years with good success. However, the custom design of implant components based on patient-specific anatomy has been attempted to overcome existing shortcomings of current designs. The longevity of cementless implant components is highly dependent on the initial fit between the bone surface and the implant. The bone-...

2011
Rudys Rodolfo DE JESUS TAVAREZ Wellington Cardoso BONACHELA Anuar Antônio XIBLE

OBJECTIVES The purpose of this in vitro study was to evaluate misfit alterations at the implant/abutment interface of external and internal connection implant systems when subjected to cyclic loading. MATERIAL AND METHODS Standard metal crowns were fabricated for 5 groups (n=10) of implant/abutment assemblies: Group 1, external hexagon implant and UCLA cast-on premachined abutment; Group 2, i...

2012
Samira Faegh Hsuan-Yu Chou Sinan Müftü

The long term success of dental implant treatment relies on the proper stability of the implant within the host bone. This condition is achieved through osseointegration, which is characterized as a direct functional and structural connection between ingrown bone tissue and implant surface (Brånemark et al., 1977; Simmons et al., 2001). Osseointegration begins with rapid growth of random and un...

Journal: :The Journal of bone and joint surgery. British volume 2005
M J Oddy C J Pendegrass A E Goodship S R Cannon T W R Briggs G W Blunn

We developed an in vivo model of the attachment of a patellar tendon to a metal implant to simulate the reconstruction of an extensor mechanism after replacement of the proximal tibia. In 24 ewes, the patellar tendon was attached to a hydroxyapatite (HA)-coated titanium prosthesis. In 12, the interface was augmented with autograft containing cancellous bone and marrow. In the remaining ewes, th...

Journal: :Journal of biomedical materials research 1997
A Berzins B Shah H Weinans D R Sumner

Push-out and pull-out tests are used for destructive evaluation of implant-bone interface strength. Because nondestructive mechanical tests would allow maintenance of an intact interface for subsequent morphological study, we developed such a test to determine the shear modulus of the interface by measuring the shear deformation of a thin layer adjacent to the implant. A polyurethane foam model...

نمودار تعداد نتایج جستجو در هر سال

با کلیک روی نمودار نتایج را به سال انتشار فیلتر کنید