نتایج جستجو برای: iodide ion
تعداد نتایج: 217976 فیلتر نتایج به سال:
a new polyvinyl choloride (pvc) membrane sensor for cerium (iii) was prepared based on 4,13-didecyl-1,7,10,16-tetraoxa-4,13-diazacyclooctadecane (kryptofix22dd) as an ionophore. the sensor exhibites a linear concentration range of 1.0×10-6to 1.0×10-1m, with a nernstian slope of 18.0±1.0 mv/decade, and a detection limit of 9.7×10-7m. it has a fast response time (5 s) and can be used for two mont...
A rapid, simple, precise and accurate method is proposed for the determination of ternary mixtures of periodate-iodate-bromate based on their reaction with iodide ion at different pH values. The absorbance was measured at 352 nm. Three sets of reaction conditions were developed. In the first set of conditions, only periodate reacted with iodide, but in the second set the periodate and iodate re...
Incubation of 5-iodo-5,6-dihydrouracil (IH2Ura) with soluble rat liver enzymes at 37 degrees, pH 8.2, results in the rapid release of iodide ion. The second product resulting from the carbon skeleton of the dihydropyrimidine ring system is 2-amino-2-oxazoline-5-carboxylic acid (I). Ultraviolet absorbance measurements at 225 nm, where both IH2Ura and iodide ion absorb, indicate that IH2Ura dehal...
Carbon-paste electrodes (CPEs) were studied to elucidate the cathodic stripping voltammetric determination of iodine. At an accumulation potential of 1.0 V (vs. SCE), iodide was preconcentrated on CPEs via an ion-pairing reaction, followed by oxidation to iodine. Then a linear scan voltammogram was recorded after 10 s of quiescent time by a cathodic potential scan from 0.7 V to 0.1 V at a scan ...
Iodide absorption by fresh, summer Lam inaria digitata frond was accompanied b y about a fivefold increase in the rate o f oxygen consumption. Betw een approxim ately 3 and 6 m ole cules o f Oa were consumed for each iodide ion absorbed by the tissue and the respiratory quotient, whether measured in the presence or absence o f iodide, lay between 0*9 and 1*1 (mean 0*94). I t is argued th a t: ...
As a part of studies concerning clinical application of the measurement of urinary iodide with an iodide-selective ion electrode, we report here the reference values for the iodide content or concentration in morning spot urine specimens from normal subjects of varying ages and studies with patients with thyroid diseases in Japan. The number distribution of the iodide content or concentration i...
We present results from all-atom molecular dynamics simulations of large-scale hydrophobic plates solvated in NaCl and NaI salt solutions. As observed in studies of ions at the air-water interface, the density of iodide near the water-plate interface is significantly enhanced relative to chloride and in the bulk. This allows for the partial hydration of iodide while chloride remains more fully ...
Non-steady-state kinetic studies reveal that the SN2 reaction between p-nitrophenoxide ion and methyl iodide in acetonitrile containing water follows a 2-step mechanism involving the formation of a kinetically significant intermediate.
In the title compound, [ZnI(2)(C(6)H(8)N(2))(2)], the Zn(II) ion is coordinated by two iodide anions and two N atoms from 2,6-dimethyl-pyrazine in a distorted tetra-hedral geometry.
A new polyvinyl choloride (PVC) membrane sensor for cerium (III) was prepared based on 4,13-didecyl-1,7,10,16-tetraoxa-4,13-diazacyclooctadecane (kryptofix22DD) as an ionophore. The sensor exhibites a linear concentration range of 1.0×10-6 to 1.0×10-1 M, with a Nernstian slope of 18.0±1.0 mV/decade, and a detection limit of 9.7×10-7 M. It has a fast response time (5 s) and can be used for two m...
نمودار تعداد نتایج جستجو در هر سال
با کلیک روی نمودار نتایج را به سال انتشار فیلتر کنید