نتایج جستجو برای: iodide ion selective electrode
تعداد نتایج: 461721 فیلتر نتایج به سال:
fluoride is recognized as an effective agent for dental caries prevention. generally, the main source of fluoride intake is drinking water. in this study, fluoride content in 18 commercial brands of bottled waters was investigated. six samples from each batch of 18 iranian commercial brands of bottled waters were supplied. the fluoride content of samples was analyzed by fluoride ion selective e...
2-amino-n-benzthioazolyl benzamide (abtb) was synthesized, characterized and used for thefabrication of a potentiometric sensor for cu2+ metal ions. the electrode exhibits linear response to cu(ii) over a wide concentration range (4.79×10 -8 – 1.85×10 -1 m) with nernstian slope of 30 ± 1.5 mvper decade. the electrode can be used in the ph range from 2 to 9. it has a fast response time of about1...
A PVC membrane incorporating p-tert-butyl calix[4]crown with imine units as an ionophore was prepared and used in an ion-selective electrode for the determination of mercury(II) ions. An electrode based on this ionophore showed a good potentiometric response for mercury(II) ions over a wide concentration range of 5.0 x 10(-5) - 1.0 x 10(-1) M with a near-Nernstian slope of 27.3 mV per decade. T...
a novel silver (ag) nanocomposite electrode was proposed that fabricated from metal nanostructures and ionic liquids. the combined application of unique properties of nanomaterials and ionic liquids in the design of this ag nanocomposite results in electrodes with interesting advantages compared to the conventional metal disk electrode. in the first part of this thesis, the elecrocatalytic eff...
In this work we introduce a practical use of synthesized Schiff base metal complex in sensing application. A new perchlorate-selective electrode based on the complex N, N'-4-nitro-phenylmethanebis-(salicylaldiminato) copper (II) [CuL] as the membrane carrier was developed. The electrode exhibits a good Nernstian slope of -55.0 ± 1.0 mV/decade and a linear range of for perchlorate. The lim...
چکیده ندارد.
An iodide-miconazole ion-paired complex was used as a suitable ion-exchanger for the preparation of a plasticized-PVC membrane electrode. Among different solvent mediators tested, dioctylsebacate exhibited the proper response characteristics, including Nernstian slope of the calibration curve, fast response time and good reproducibility of the emf values. The electrode exhibits a Nernstian slop...
a new poly(vinylchloride) membrane sensor for cr3+ ions based on di (benzylamino)glyoxime asan ionophore was prepared. the electrode has a linear dynamic range 1×10-6-1×10-1 mol l-1,with anernstian slope of 20.3 ± 0.5 mv per decade and a detection limit of 2×10-7. it has a fast responsetime of
نمودار تعداد نتایج جستجو در هر سال
با کلیک روی نمودار نتایج را به سال انتشار فیلتر کنید