2017
Adam D. Yock Gwe‐Ya Kim

PURPOSE To present the k-means clustering algorithm as a tool to address treatment planning considerations characteristic of stereotactic radiosurgery using a single isocenter for multiple targets. METHODS For 30 patients treated with stereotactic radiosurgery for multiple brain metastases, the geometric centroids and radii of each met were determined from the treatment planning system. In-ho...

Journal: :Medical physics 2002
Zhe Chen Lei Xing Ravinder Nath

A self-consistent monitor unit (MU) and isocenter point-dose calculation method has been developed that provides an independent verification of the MU for intensity modulated radiotherapy (IMRT) using the MIMiC (Nomos Corporation) multileaf collimator. The method takes into account two unique features of IMRT using the MIMiC: namely the gantry-dynamic arc delivery of intensity modulated photon ...

2010
Max Seidensticker Peter Wust Ricarda Rühl Konrad Mohnike Maciej Pech Gero Wieners Günther Gademann Jens Ricke

BACKGROUND Micrometastases of colorectal liver metastases are present in up to 50% of lesions. In this study we sought to determine the threshold dose for local control of occult micrometastases in patients undergoing CT (computed tomography)-guided brachytherapy of colorectal liver metastases. MATERIALS AND METHODS Nineteen patients demonstrated 34 local tumor recurrences originating from mi...

2011
Giuseppe Minniti Claudia Scaringi Enrico Clarke Maurizio Valeriani Mattia Osti Riccardo Maurizi Enrici

PURPOSE To assess the accuracy of patient repositioning and clinical outcomes of frameless stereotactic radiosurgery (SRS) for brain metastases using a stereotactic mask fixation system. PATIENTS AND METHODS One hundred two patients treated consecutively with frameless SRS as primary treatment at University of Rome Sapienza Sant'Andrea Hospital between October 2008 and April 2010 and followed...

2012
Feliciano García‐Vicente Virginia Fernández Rocío Bermüdez Alberto Gómez Leopoldo Pérez Almudena Zapatero Juan J. Torres

The aim of this study is to determine the gantry angle and multileaf collimator (MLC) gap error-detection threshold of a diode helical array with an inserted micro-ionization chamber in order to use this device for the pretreatment quality assurance (QA) of intensity-modulated radiation therapy (IMRT) treatments. Implications on the dose-volume histograms (DVHs) of the patient treatments will a...

2015
Liyun Chang Sheng‐Yow Ho Shyh‐An Yeh Tsair‐Fwu Lee Pang‐Yu Chen

Brachytherapy used in local cervical cancer is still widely based on 2D standard dose planning with the prescription to point A, which is invisible on imaging and located at a high-dose gradient. In this study, the geometric location error of point A was investigated. It is traditionally reconstructed in the treatment planning system after carefully digitizing the point marks that were previous...

2018
Åse Ballangrud Li Cheng Kuo Laura Happersett Seng Boh Lim Kathryn Beal Yoshiya Yamada Margie Hunt James Mechalakos

BACKGROUND AND PURPOSE This study summarizes the cranial stereotactic radiosurgery (SRS) volumetric modulated arc therapy (VMAT) procedure at our institution. MATERIALS AND METHODS Volumetric modulated arc therapy plans were generated for 40 patients with 188 lesions (range 2-8, median 5) in Eclipse and treated on a TrueBeam STx. Limitations of the custom beam model outside the central 2.5 mm...

Journal: :Medical physics 2012
D Hyer C Mart

PURPOSE The aim of this study was to develop a phantom and analysis software that could be used to quickly and accurately determine the location of radiation isocenter using the Electronic Portal Imaging Device (EPID). The phantom could then be used as a static reference point for performing other tests including: radiation vs. light field coincidence, MLC and Jaw strip tests, and Varian Optica...

Journal: :Japanese Journal of Radiological Technology 1995

2005
Harish K. Malhotra Sanjay Raina Jaiteerth S. Avadhani Steven deBoer Matthew B. Podgorsak

The maximum width of an intensity-modulated radiotherapy (IMRT) treatment field is usually smaller than the conventional maximum collimator opening because of design limitations inherent in some multileaf collimators (MLCs). To increase the effective field width, IMRT fluences can be split and delivered with multiple carriage positions. However, not all treatment-planning systems and MLCs suppo...