نتایج جستجو برای: line detectors

تعداد نتایج: 443077  

Journal: :CoRR 2014
Adrien Gaidon Gloria Zen José A. Rodríguez-Serrano

Learning object detectors requires massive amounts of labeled training samples from the specific data source of interest. This is impractical when dealing with many different sources (e.g., in camera networks), or constantly changing ones such as mobile cameras (e.g., in robotics or driving assistant systems). In this paper, we address the problem of self-learning detectors in an autonomous man...

1999
Thomas A. Moore Ronald W. Hellings

The era of gravitational astronomy is nearly here. In the next few years, ground-based laser gravitational wave detectors will begin to come on line and, it is hoped, space-based detectors will soon follow. Even if the ground-based detectors do not succeed in detecting the waves within the next decade, the space-based detectors will certainly be able to, so the physics goal of the detection of ...

پایان نامه :وزارت علوم، تحقیقات و فناوری - دانشگاه صنعت آب و برق (شهید عباسپور) - دانشکده مهندسی برق و کامپیوتر 1392

abstract according to increase in electricity consumption in one hand and power systemsreliability importance in another , fault location detection techniqueshave beenrecentlytaken to consideration. an algorithm based on collected data from both transmission line endsproposed in this thesis. in order to reducecapacitance effects of transmission line, distributed parametersof transmission line...

2002
Adam Kristof

Presented method of on-line detection of overloads and short circuits in digital devices and systems is based on inexpensive overload detectors built into integrated circuits. A prototype 0.8 μm CMOS ASIC successfully verifies this method.

and G. Mirjalily, M. Ghaffari, M.M. Nayebi, M.R. Taban,

In this paper, two suboptimum detectors are proposed for coherent radar signal detection in K-distributed clutter. Assuming certain values for several initial moments of clutter amplitude, the characteristic function of the clutter amplitude is approximated by a limited series. Using the Pade approximation, it is then converted to a rational fraction. Thus, the pdf of the clutter amplitude is o...

2010
A. Monfardini L. J. Swenson A. Bideaud F. X. Désert S. J. C. Yates A. Benoit A. M. Baryshev J. J. A. Baselmans S. Doyle B. Klein M. Roesch C. Tucker P. Ade M. Calvo P. Camus C. Giordano K. F. Schuster

Context. Current generation millimeter wavelength detectors suffer from scaling limits imposed by complex cryogenic readout electronics. These instruments typically employ multiplexing ratios well below a hundred. To achieve multiplexing ratios greater than a thousand, it is imperative to investigate technologies that intrinsically incorporate strong multiplexing. One possible solution is the k...

and G. Mirjalily, M. Ghaffari, M.M. Nayebi, M.R. Taban,

In this paper, two suboptimum detectors are proposed for coherent radar signal detection in K-distributed clutter. Assuming certain values for several initial moments of clutter amplitude, the characteristic function of the clutter amplitude is approximated by a limited series. Using the Pade approximation, it is then converted to a rational fraction. Thus, the pdf of the clutter amplitude is o...

Journal: :iranian journal of radiation research 0
m. allahverdi department of medical physics, cancer institute, tehran university of medical sciences, tehran, iran m.r. taghizadeh department of radiotherapy, imam khomeini hospital, tehran university of medical sciences, tehran, iran

abstract background: in vivo measurements of applied dose during radiotherapy treatment, is important to ensure accurate dose delivery to patients. uncertainty in dose delivery should fall within ±5% of the prescribed dose as recommended by icru. assessment of dose for radiotherapy applications performed with various types of detectors. in this study, semiconductor diodes were used which have s...

نمودار تعداد نتایج جستجو در هر سال

با کلیک روی نمودار نتایج را به سال انتشار فیلتر کنید