نتایج جستجو برای: magnetic device

تعداد نتایج: 989267  

Journal: :razavi international journal of medicine 0
mohammad hosein ebrahimzadeh orthopedic research center, department of orthopedic surgery, mashhad university of medical sciences, mashhad, ir iran hamid farzadfar orthopedic research center, department of orthopedic surgery, mashhad university of medical sciences, mashhad, ir iran hami ashraf department of research and education, razavi hospital, mashhad, ir iran gholam reza khoshsima orthopedic research center, department of orthopedic surgery, mashhad university of medical sciences, mashhad, ir iran ali birjandinejad orthopedic research center, department of orthopedic surgery, mashhad university of medical sciences, mashhad, ir iran; orthopedic research center, department of orthopedic surgery, mashhad university of medical sciences, mashhad, ir iran. tel: +98-5138523300, fax: +98-5138549234

conclusions we found the magnetic field assistant device to be an accurate, radiation-independent jig for close passing of guide wire after close reduction of femoral fracture. it can reduce the need for radiation during placement of guide wire for closed intramedullary nailing of the long bones. more studies are required to improve and evaluate the technique and equipment. results outcomes of ...

Journal: :Heart rhythm 2007
Thomas Wolber Salome Ryf Christian Binggeli Johannes Holzmeister Corinna Brunckhorst Roger Luechinger Firat Duru

BACKGROUND Magnetic fields may interfere with the function of cardiac pacemakers and implantable cardioverter-defibrillators (ICDs). Neodymium-iron-boron (NdFeB) magnets, which are small in size but produce strong magnetic fields, have become widely available in recent years. Therefore, NdFeB magnets may be associated with an emerging risk of device interference. OBJECTIVE We conducted a clin...

2016
Prasenjit Chatterjee Hwang-Cherng Chow Wu-Shiung Feng

This paper reports a detailed analysis of the drain current modulation of a single-drain normal-gate n channel metal-oxide semiconductor field effect transistor (n-MOSFET) under an on-chip magnetic field. A single-drain n-MOSFET has been fabricated and placed in the center of a square-shaped metal loop which generates the on-chip magnetic field. The proposed device designed is much smaller in s...

Journal: :IBM Journal of Research and Development 2006
William J. Gallagher Stuart S. P. Parkin

This paper reviews the remarkable developments of the magnetic tunnel junction over the last decade and in particular, work aimed at demonstrating its potential for a dense, fast, and nonvolatile random access memory. The initial focus is on the technological roots of the magnetic tunnel junction, and then on the recent progress made with engineered materials for this device. Following that, we...

In oil industries, water injection into oil reservoirs for pressure maintenance, oil displacement, and oil recovery is a common technique. Formation damage during water injection is a major problem in this process. Formation damage from the incompatibility of formation water (FW) and injection water (IW) causes a reduction in the permeability around the injection wells. Therefore, it is necessa...

2009
Qirui Wang Jianping Hu Qi Liu Junchao Yan

In order to improve Multi-polar magnetic structure’s efficiency. Ansoft Maxwell of electromagnetic field finite element software is utilized to study the effect of different polarity arrangement of magnetic seeding element on the magnetic induction intensity of seeding element end and magnetic field distribution in the seeding air gap. As a result of the different electromagnetic coil current d...

2002
S. I. Krasheninnikov L. E. Zakharov G. V. Pereverzev

It is shown that lithium walls resulting in zero recycling conditions at the edge of magnetic fusion device can cause drastic reduction of heat conduction energy loss from the core and, therefore, can crucially alter the performance of magnetic fusion device.

Journal: :IJMHCI 2013
Hamed Ketabdar Amin Haji Abolhassani Mehran Roshandel

The theory of around device interaction (ADI) has recently gained a lot of attention in the field of human computer interaction (HCI). As an alternative to the classic data entry methods, such as keypads and touch screens interaction, ADI proposes a touchless user interface that extends beyond the peripheral area of a device. In this paper, we propose a new approach for around mobile device int...

Journal: :Technology and health care : official journal of the European Society for Engineering and Medicine 2015
Zuhe Wu Zihang Zhuo Dongyang Cai Jian'an Wu Jie Wang Jintian Tang

BACKGROUND Induction heating devices using the induction coil and magnetic nanoparticles (MNPs) are the way that the magnetic hyperthermia is heading. OBJECTIVE To facilitate the induction heating of in vivo magnetic nanoparticles in hyperthermia experiments on large animals. METHODS An induction heating device using a planar coil was designed with a magnetic field frequency of 328 kHz. The...

Journal: :Physical review letters 2014
S I Kulinich L Y Gorelik A N Kalinenko I V Krive R I Shekhter Y W Park M Jonson

A nanoelectromechanical device based on magnetic exchange forces and electron spin flips induced by a weak external magnetic field is suggested. It is shown that this device can operate as a new type of single-electron "shuttle" in the Coulomb blockade regime of electron transport.

نمودار تعداد نتایج جستجو در هر سال

با کلیک روی نمودار نتایج را به سال انتشار فیلتر کنید