نتایج جستجو برای: mammosite applicator

تعداد نتایج: 1992  

Journal: :Brachytherapy 2003
John C Roeske Christina Lund Charles A Pelizzari Xiaochuan Pan Arno J Mundt

PURPOSE To evaluate a method of reducing computed tomography (CT) metal artifacts due to the Fletcher-Suit applicator. METHODS AND MATERIALS We apply a projection-interpolation algorithm to CT images containing artifacts from the brachytherapy applicator. Regions of projection data containing the applicator are interpolated, removing the metal from the projections. A new image is then reconst...

Journal: :Asian Pacific journal of cancer prevention : APJCP 2015
Dan Shi Ming-Yuan He Zhi-Peng Zhao Ning Wu Hong-Fu Zhao Zhi-Jian Xu Guang-Hui Cheng

BACKGROUND For brachytherapy of cervical cancer, applicator shifts can not be avoided. The present investigation concerned Utrecht interstitial applicator shifts and their effects on organ movement and DVH parameters during 3D CT-based HDR brachytherapy of cervical cancer. MATERIALS AND METHODS After the applicator being implanted, CT imaging was achieved for oncologist contouring CTVhr, CTVi...

Journal: :Physics in medicine and biology 2014
Gabriel Paiva Fonseca Guillaume Landry Shane White Michel D'Amours Hélio Yoriyaz Luc Beaulieu Brigitte Reniers Frank Verhaegen

Accounting for brachytherapy applicator attenuation is part of the recommendations from the recent report of AAPM Task Group 186. To do so, model based dose calculation algorithms require accurate modelling of the applicator geometry. This can be non-trivial in the case of irregularly shaped applicators such as the Fletcher Williamson gynaecological applicator or balloon applicators with possib...

2006
Nagarajan Vivekanandan Bhuvana Kunjithapatham Nithya Kanakavelu Balakrishnan Shankarrao Irde Lakshmanan Alathurmadam Vaidyanathan

In CT anatomy-based inverse treatment planning of interstitial high-dose rate (HDR) brachytherapy planning, the planning target volume (PTV) delineated by the radiation oncologist includes the applicator volume. The applicator volume can be eliminated with the help of two methods: one based on Boolean operations and the other using the erasing option of the application software. Both methods ar...

Introduction: Brachytherapy is a type of radiotherapy in which radioactive sources are used in proximity of tumors normally for treatment of malignancies in the head, prostate and cervix. Materials and Methods: The Cs-137 Selectron source is a low-dose-rate (LDR) brachytherapy source used in a remote afterloading system for treatment of different cancers. This system uses active and inactive sp...

2017
Bikramjit Chakrabarti Somapriya Basu-Roy Sanjay Kumar Kar Sounik Das Annesha Lahiri

Purpose This study is intended to compare dose-volume parameters evaluated using different forward planning- optimization techniques, involving two applicator systems in intracavitary brachytherapy for cervical cancer. It looks for the best applicator-optimization combination to fulfill recommended dose-volume objectives in different high-dose-rate (HDR) fractionation schedules. Material and ...

2005
Slobodan Devic Té Vuong Belal Moftah

High-dose rate endorectal brachytherapy (HDR-EBT) is mainly used as a palliative treatment modality. In this paper, we compare dosimetry distributions for a single-channel catheter (Miami) applicator with distributions of the inflatable multichannel (Novi Sad) endorectal applicator. The comparisons were made with respect to dose coverage to the clinical tumor volume as well as to the bladder, r...

2016
Emily Flower Kathy Ngoc Tran Salman Zanjani Wayne Smith Jonathan Karpelowsky Katie Summerhayes Edgar Estoesta Jennifer Chard

PURPOSE To report peri-operative fractionated high-dose-rate (HDR) brachytherapy with a 3D customized Freiburg flap applicator to treat locally recurrent Wilms' tumor, followed by immediate hyperthermic intraperitoneal chemotherapy for a 16-year-old with a second recurrence of nephroblastoma (Wilms' tumor). MATERIAL AND METHODS The tumor was excised and surgical bed was treated with fractiona...

2009
Jaroslav Vorlíček Jan Rusz

This article deals with the design and construction of the microwave applicator with transversal electro-magnetic (TEM) wave, which is filled by distilled water. We have constructed an applicator that works on the frequency f = 434MHz with aperture size of 100mm x 75mm. The applicator is made of the copper. Design of dimensions of the applicator and simulation of the specific absorption rate (S...

2001
Michael D. Mills Liliosa C. Fajardo David L. Wilson Jodi L. Daves William J. Spanos

Radiation performance characteristics of a dedicated intraoperative accelerator were determined to prepare the unit for clinical use. The linear accelerator uses standing wave X-band technology (wavelength approximately 3 centimeters) in order to minimize the mass of the accelerator. The injector design, smaller accelerator components, and low electron beam currents minimize radiation leakage. ...

نمودار تعداد نتایج جستجو در هر سال

با کلیک روی نمودار نتایج را به سال انتشار فیلتر کنید