نتایج جستجو برای: mcnp
تعداد نتایج: 925 فیلتر نتایج به سال:
The biological effects of acute, high doses of radiation are well understood. However, the effects of chronic, low doses are not as clear. Mice irradiation experiments to study the correlation of biological effects with chronic low dose rates are underway in order to make conclusions about the effects of low doses. Yet, in order to do so, the level of dose provided to the animals must be determ...
براکی تراپی، روشی در پرتو درمانی است که در آن از چشمه های رادیواکتیو ویژه ای در فاصله ی نزدیک، در تماس یا کاشت در تومور، برای درمان استفاده می شود به طوری که بافت آسیب دیده بیشترین دز را دریافت کرده در حالی که به بافت های سالم اطراف آن آسیب کمتری برسد. چشمه ها ی 103pd و 125i به طور گسترده در درمان تومورهای بدخیم استفاده می شوند. در سال 1986 چشمه 103pdبه عنوان یک انتخاب مناسب برای جایگزینی چشم...
As the input of MCNP code (Monte Carlo N - Particle code system), a monoenergetic and isotropic point source with the energy rangeg from 0.3 to 10 MeV was placed at the center of a spherical material surrounded by another one. The first shielding material was water and the second one was lead. The total thickness of the shield varied between 2 to 10 mfp. Then, using the output of MCNCP, exposur...
Genetic algorithms (GA) are used to optimize the Fast Neutron Source (FNS) core fuel loading maximize a multiobjective function. The FNS has 150 material locations that can be loaded with one of three different materials resulting in over 3E+71 combinations. individual designs evaluated computationally intensive calls MCNP. To speed up optimization, convolutional neural networks (CNN) trained a...
Prompt-gamma activation analysis (PGAA) has been extended and validated to measure large irregularly shaped samples. The detailed sample geometry was implemented in the MCNP-model of setup accurate matrix-effect corrections were obtained.
The Paper describes basic information about MCNP calculations and experimental measurements at the VR-1 reactor and their evaluation. The preparation of calculations and verification of the experiments are integral part of the VR-1 reactor operation. The neutronics calculations and analyses are often necessary condition to gain the approval to experiments realization at the reactor VR-1. The pa...
This document presents the process for a new method developed characterization of delayed gamma-ray radiation fields in pulse reactors like Annular Core Research Reactor (ACRR). The environments used to test this ACRR Central Cavity were various standard irradiation configurations that amounts moderators and shielding. All environment same fission product source energy spectrum. required use si...
Abstract The Cs 2 LiYCl 6 :Ce crystal (CLYC) is an inorganic scintillator which has been developed for the γ-ray and neutron measurement with high detection efficiency, resolution, no need unfolding technique. To enhance of fast neutron, CLYC 7 Li-enrichment (CLYC7) developed. In this work, response CLYC7 detector to obtained using 137 calibration source calculated Monte Carlo N-Particle transp...
Response functions of a 3×3 in. NaI detector, which is mainly used in PGNAA applications, have been calculated by using MCNP-4C code. Calculated results are compared with measured data by using standard γ-ray sources to check their accuracy. γ-rays from radioisotope sources were used in the range from 0.081 to 4.438 MeV for this determination. Through the precise modeling of the detector struct...
Response functions of a 3×3 in. NaI detector, which is mainly used in PGNAA applications, have been calculated by using MCNP-4C code. Calculated results are compared with measured data by using standard -ray sources to check their accuracy. -rays from radioisotope sources were used in the range from 0.081 to 4.438 MeV for this determination. Through the precise modeling of the detector structur...
نمودار تعداد نتایج جستجو در هر سال
با کلیک روی نمودار نتایج را به سال انتشار فیلتر کنید