نتایج جستجو برای: meteorological tower
تعداد نتایج: 32560 فیلتر نتایج به سال:
Design of a natural dry cooling tower has been accomplished in two sections: the design of heat exchangers and the numerical solution of flow through the tower. Heat exchanger (Heller type) has been simulated thermodynamically and then coupled with a computer program, which calculated the turbulent natural convection flow through the tower. The computer program developed for this purpose can be...
drought is transient phenomenon , slow , repetitive and integral part of the climate of each region. drought begins with a substantial reduction in precipitation over the long-term average rainfall and over time, reduced soil moisture and surface and ground water resources will continue to decrease. this phenomenon is the most important in bakhtegan basin because of its importance in strategic ...
Abstract. The surface pressure fluctuations, which are a source of low-frequency noise emissions, numerically investigated on 2 MW wind turbine under different inflow conditions. In order to evaluate the impact complex-terrain flow, computational setup is presented that aimed at reproducing realistic flow field in complex terrain Perdigão, Portugal. A precursor simulation with steady-state atmo...
The present paper describes the designing of a thermally and economically optimum mechanical draft counter-flow wet cooling tower. The design model allows the use of a variety of packing materials in the cooling tower toward optimizing heat transfer. Once the optimum packing type is chosen, a compact cooling tower with low fan power consumption is modelled within the known design variables....
since the energy analysis considers the quantity of energy, it cannot show the performance of the cooling tower. therefore, in order to optimize the performance of the tower and also the process which the cooling tower is a part of it, it is necessary to analyze the energy and exergy of the tower simultaneously. in this paper, the energy and exergy of one of the cooling towers of khuzestan stee...
Large eddy simulation (LES) of the atmospheric boundary layer (ABL) flow over complex terrain is presented with a validation using meteorological tower (met-tower) data through an improved neutral stability sampling approach. The proposed procedure includes condition based on most-likely occurrence time-periods ABL and reduces variabilities conditional wind statistics calculated at met-towers i...
ghorban tower as an architectural monument is one of the outstanding resting- place of islamic era in hamadan city which has not been studied properly. previous studies on the tower concerning its architectural features or its historical background showed that the tower may be a place where a dignified religious man named khajeh hafez abol'ala hamadani berried inside in saljuk era and afte...
temperature restrictions on aqueous effluents dictate that streams with a temperature higher than the permitted level needed to pass through cooling systems to reduce the effluent temperature before discharge. in this study, by considering the grouping design rules based on pinch technology, an optimum design for a distributed effluent cooling system, has been developed. a counter-flow wet cool...
Ecosystem productivity models rely on regional climatic information to estimate temperature and moisture constraints influencing plant growth. However, the productivity response to these environmental factors is uncertain at the global scale and has largely been defined using limited observations from sparse monitoring sites, including carbon flux towers. Recent studies have shown that satellit...
نمودار تعداد نتایج جستجو در هر سال
با کلیک روی نمودار نتایج را به سال انتشار فیلتر کنید