نتایج جستجو برای: nonlinear response history analysis

تعداد نتایج: 4042897  

Journal: :journal of structural engineering and geo-techniques 2012
f. barati a. esfandiari

in this paper, seismic behavior of the existing buildings equipped by friction dampers is studied. seismic performance of6-story, 9-story and 12-story steel buildings with damper and without damper were studied. the finite element modeling technique (sap2000 software) is used for analysis. time history analyzing was done to achieve this purpose. for nonlinear dynamic analysis, the responses of ...

A. Haghighi, H. M. Vali Samani, M. H. Ranginkaman,

Inverse Transient Analysis (ITA) is a powerful approach for leak detection of pipelines. When the pipe transient flow is analyzed in frequency domain the ITA is called Inverse Frequency Response Analysis (IFRA). To implement an IFRA for leak detection, a transient state is initiated in the pipe by fast closure of the downstream end valve. Then, the pressure time history at the valve location is...

Incremental Dynamic Analysis (IDA) procedure is now considered as a robust tool for estimating the seismic sidesway collapse capacity of structures. However, the procedure is time-consuming and requires numerous nonlinear response-history analyses. This paper proposes a simplified Modal Pushover Analysis (MPA) procedure for IDA of RC moment-resisting frames. The proposed method uses the dynamic...

Rapid evaluation of demand parameters of different types of  buildings is crucial for social restoration after damaging earthquakes. Previous studies proposed numerous methodologies to measure the performance of buildings for assessing the potential risk under the seismic hazard. However, time-consuming Nonlinear Response History Analysis (NRHA) barricaded implementing a prompt loss estimation ...

Journal: :international journal of civil engineering 0
m. mahmoudi shahid rajaee teacher training university t. teimoori shahid rajaee teacher training university h. kozani shahid rajaee teacher training university

the current building codes provide limited prescriptive guidance on design for protection of buildings due to progressive collapse. progressive collapse is a situation in which a localized failure in a structure, caused by an abnormal load, such as explosions or other happenings. three procedures, often employed for determination of the structural response during progressive collapse i.e. linea...

In this paper, transverse and longitudinal vibration of nonlinear plate under exciting of orbiting mass is considered based on first-order shear deformation theory. The nonlinear governing equation of motion are discretized by the finite element method in combination with Newmark’s time integration scheme under von Karman strain-displacement assumptions. For validation of method and formulation...

Journal: :civil engineering infrastructures journal 0
gholamreza abdollahzadeh assistant professor, faculty of civil engineering, babol university of technology hamidreza malekzadeh department of civil engineering, college of engineering, university of shomal, amol, iran

the present research is concerned with the determination of ductility, over-strength and response modification factors of coupled steel shear wall frames. three structural models with various numbers of stories, bay width and coupling beam height were analyzed using static pushover and incremental nonlinear dynamic analyses. the ductility, over-strength and response modification factors for the...

M Hosseini S.M.R Khalili,

In this paper, static indentation and low velocity impact responses of a fully backed composite sandwich plate subjected to a rigid flat-ended cylindrical indenter/impactor are analytically investigated. The analysis is nonlinear due to nonlinear strain-displacement relation. In contrast to the existed analytical models for the indentation of composite sandwich plates, the stacking sequence of ...

ژورنال: مهندسی دریا 2014

In this research, the response of fixed offshore platforms equipped with shape memory alloy elements at the different depths under extreme wave loading are taken into account. For this purpose platforms located in different water depths 70, 110 and 150 has been considered. At first for evaluation of the nonlinear behavior of three platforms, pushover analysis using SACS has been engaged. Then n...

نمودار تعداد نتایج جستجو در هر سال

با کلیک روی نمودار نتایج را به سال انتشار فیلتر کنید