نتایج جستجو برای: optode

تعداد نتایج: 246  

2014
Mai T. Thao Daniel Perez James Dillon Elizabeth R. Gaillard

PURPOSE To obtain a better understanding of oxygen and nutrient transport within the lens, the viscosity of whole lenses was investigated using a fiber optic oxygen sensor (optode). The diffusion coefficient of oxygen was calculated using the Stokes-Einstein equation at the slip boundary condition. METHODS The optode was used to measure the oxygen decay signal in samples consisting of differe...

2014
Henry C. Bittig Björn Fiedler Roland Scholz Gerd Krahmann Arne Körtzinger

The time response behavior of Aanderaa optodes model 3830, 4330, and 4330F, as well as a Sea-Bird SBE63 optode and a JFE Alec Co. Rinko dissolved oxygen sensor was analyzed both in the laboratory and in the field. The main factor for the time response is the dynamic regime, i.e., the water flow around the sensor that influences the boundary layer’s dynamics. Response times can be drastically re...

Journal: :Limnology and Oceanography-methods 2023

The aquatic eddy covariance technique is increasingly used to determine oxygen (O2) fluxes over benthic ecosystems. uses O2 measuring systems that have a high temporal and numerical resolution. In this study, we performed series of lab field tests assess new optical submersible meter designed for measurements equipped with an existing ultra-high speed fiber sensor. has 16-bit digital-to-analog-...

2007
Jee Hyun Choi Martin Wolf Vlad Toronov Antonios Michalos Ursula Wolf Enrico Gratton

Cerebral vasomotion was studied on the human brain in vivo by use of multi-optode frequency domain near-infrared spectroscopy (NIRS). Vasomotion is a spontaneous oscillation with a frequency of 0.1Hz in the arterial flow. We investigated (1) the fluctuations of cerebral hemodynamics on the dynamical characteristics of cerebral vasomotion and (2) the dynamical coupling between vasomotion in the ...

Journal: :Optics express 2001
A Bluestone G Abdoulaev C Schmitz R Barbour A Hielscher

We report on the first three-dimensional, volumetric, tomographic localization of vascular reactivity in the brain. To this end we developed a model-based iterative image reconstruction scheme that employs adjoint differentiation methods to minimize the difference between measured and predicted data. The necessary human-head geometry and optode locations were determined with a photogrammetric m...

2012
Patricia Brunner Christian Clason Manuel Freiberger Hermann Scharfetter

A novel approach is presented for computing optode placements that are adapted to specific geometries and tissue characteristics, e.g., in optical tomography and photodynamic cancer therapy. The method is based on optimal control techniques together with a sparsity-promoting penalty that favors pointwise solutions, yielding both locations and magnitudes of light sources. In contrast to current ...

2012
Xiaojiang Xie Günter Mistlberger Eric Bakker

We report here for the first time on a reversible photodynamic bulk optode sensor based on the photoswitching of a spiropyran derivative (Sp). The photoswitching of Sp induces a large basicity increase in the polymeric phase, which triggers the extraction of Cl(-) and H(+). Cl(-) is stabilized by a lipophilic chloride-selective ionophore inside the membrane, while H(+) binds with the open form ...

نمودار تعداد نتایج جستجو در هر سال

با کلیک روی نمودار نتایج را به سال انتشار فیلتر کنید