نتایج جستجو برای: photon field size

تعداد نتایج: 1356235  

2008
S. Glancy J. M. LoSecco C. E. Tanner

We show that the optical Kerr effect can be used to construct a quantum phase gate. It is well known from quantum nondemolition techniques that, as two photon field modes pass through a Kerr medium, the phase of each mode will be shifted, and the size of the phase shift will depend on the number of photons in both modes. We discuss the Hamiltonian responsible for this effect and show how this c...

Purpose: Fiber carbon is the most common material used in treating couch as it causes less beam attenuation than other materials. Beam attenuation replaces build-up region, reduces skin-sparing effect and causes target volume under dosage. In this study, we aimed to evaluate beam attenuation and variation of build-up region in 550 TxT radiotherapy couch.Materials and Methods: In this study, we ...

Background: External beam radiation therapy is often administered to patients implanted with silicone gel breast prosthesis. The aim of this study was to investigate the influence of silicone gel breast prosthesis on photon dose distributions. In the event of recurrence, the oncologist may be forced to irradiate through the prosthetic device. To quantify the dose enhancement or reduction below ...

Journal: :iranian journal of radiation research 0
m. allahverdi department of medical physics and biomedical engineering, tehran university of medical sciences, tehran, iran m. zabihzadeh department of medical physics, jondishapour university of medical sciences, ahvaz, iran m.r. ay department of medical physics and biomedical engineering, tehran university of medical sciences, tehran, iran s.r. mahdavi department of medical physics, iran university of medical sciences, tehran, iran m. shahriari department of nuclear engineering, shahid beheshti university, tehran, iran a. mesbahi department of medical physics, tabriz university of medical sciences, tabriz, iran

background: the electron contamination may reduce or even diminish the skin sparing property of the megavoltage beam. the detailed characteristics of contaminant electrons are presented for different field sizes and cases. materials and methods: the monte carlo code, mcnpx, has been used to simulate 18 mv photon beam from a varian linac-2300 accelerator. all dose measurements were carried out u...

پایان نامه :وزارت علوم، تحقیقات و فناوری - دانشگاه ارومیه - دانشکده علوم 1387

چکیده ندارد.

Journal: :iranian journal of radiation research 0
t. siji cyriac department of physics, noorul islam centre for higher education, kumaracoil, thuckalay, kanyakumari district, 629 180, tamilnadu, india m.m. musthafa department of physics, university of calicut, thenhipalam, malappuram, 673 635, kerala, india r. ganapathi raman department of physics, noorul islam centre for higher education, kumaracoil, thuckalay, kanyakumari district, 629 180, tamilnadu, india k. abdul haneefa infn and department of physics, university of torino, via p. giuria, 10125, torino, italy saju bhasi department of radiation physics, regional cancer center, trivandrum, 695 011 , kerala, india

background: the present work aims to study the out-of-field photon calculation accuracy of a commercial treatment planning system (tps), oncentra, for three-dimensional conformal radiotherapy (3d-crt) and intensity modulated radiation therapy (imrt) treatment techniques from elekta synergy medical linear accelerator. materials and methods: accuracy of individual out-of-field dose components was...

A Chairmadurai C Bhatt D Shrotiya L Chaudhari N Painuly, N Singh, T Verma

Aims: The aims of the present work are (1) to evaluate dose calculation accuracy of two commonly used algorithms for 15 MV small photon fields in a medium encompassing heterogeneity and (2) to compare them with measured results obtained from gafchromic film EBT2.Materials and Methods: Authors employed kailwood (Pinus Wallichiana) to mimic lung. Briefly, seven Kailwood plates, each measuring 25x...

ژورنال: سنجش و ایمنی پرتو 2017

Recent studies suggest that relative biological damage (RBD) may change from in to out of field regions for 6 MV photon beams. In this study RBD was calculated in and out of field of 30x30 cm2 and 40x40 cm2 6 MV clinical photon beams including low energy slowing down electrons in track length estimated method. Varian 2100C/D linear accelerator was simulated using MCNPX code. Electron and photon...

Journal: :iranian journal of radiation research 0
m.n. anjum a. qadir m. afzal

background: the dosimetric performance of eclipse 6.5 three dimensional treatment planning system (3dtps) is evaluated by comparing the calculated and measured dose in two dimensions following the guide lines of american association for physicists in medicine task group 53. materials and methods: the calculations were performed by the 3dtps for symmetric as well as asymmetric fields for standar...

Journal: :Physical review. E, Statistical physics, plasmas, fluids, and related interdisciplinary topics 2000
X Li D N Pattanayak T Durduran J P Culver B Chance A G Yodh

An angular spectrum algorithm is presented for fast, near-field diffraction tomographic imaging with diffuse photon density waves in highly scattering media. A general relation in K space is derived that connects the spatial variations of the optical properties of heterogeneities to the spatial spectra of the measured scattered diffuse photon density waves. The theory is verified experimentally...

نمودار تعداد نتایج جستجو در هر سال

با کلیک روی نمودار نتایج را به سال انتشار فیلتر کنید