نتایج جستجو برای: piece abutment

تعداد نتایج: 32845  

Journal: :journal of dentistry, tehran university of medical sciences 0
mitra farzin associate professor, department of prosthodontics faculty of dentistry, shiraz university of medical science, shiraz, iran. kianoosh torabi associate professor, depatment of prosthodontics, biomaterial research center faculty of dentistry, shiraz, iran. ahmad hasan ahangari associate professor, department of prosthodontics faculty of dentistry, shiraz university of medical science, shiraz, iran. reza derafshi assistant professor, department of prostodontics faculty of dentistry, shiraz university of medical science, shiraz, iran.

provisional cements are commonly used to facilitate retrievability of cement-retained fixed implant restorations; but compromised abutment preparation may affect the retention of implant-retained crowns.the purpose of this study was to investigate the effect of abutment design and type of luting agent on the retentive strength of cement-retained implant restorations.two prefabricated abutments ...

2017
David Y L Chan Tin Chiu Li

We aim to visualize the external physical damages and distinct external phenotypic effects between mechanical and laser-assisted immobilized human spermatozoa using scanning electronic microscopy (SEM). Human spermatozoa were immobilized mechanically or with laser assistance for SEM examination and the membrane integrities were checked on both types of immobilized spermatozoa. We found evidence...

2009
Seung-Jin Moon Hee-Jung Kim Mee-Kyoung Son Chae-Heon Chung

STATEMENT OF PROBLEM Unlike screw-retention type, fixture-abutment retention in Locking taper connection depends on frictional force so it has possibility of abutment to sink. PURPOSE In this study, Bicon® Implant System, one of the conical internal connection implant system, was used with applying loading force to the abutments connected to the fixture. Then the amount of sinking was measure...

Journal: :The International journal of oral & maxillofacial implants 2011
Michael W Klotz Thomas D Taylor A Jon Goldberg

PURPOSE The purpose of this study was to use a clinical simulation to determine whether wear of the internal surface of a titanium implant was greater following connection and loading of a one-piece zirconia implant abutment or a titanium implant abutment. MATERIALS AND METHODS Two implants received zirconia abutments and two received titanium abutments. The implants were secured into four fi...

Journal: :journal of dentistry, tehran university of medical sciences 0
simindokht zarrati mehran bahrami fatemeh heidari jamal kashani

objectives : this finite element method study aimed to compare the amount of stress on an isolated mandibular second premolar in two conventional reciprocal parallel interface designs of removable partial dentures (rpds) and the same rpd abutment tooth (not isolated). materials and methods: a kennedy class 1, modification 1 rpd framework was simulated on a 3d model of mandible with three differ...

Journal: :General dentistry 2018
Feras Al Rezk Georgia Trimpou Hans-Christoph Lauer Paul Weigl Nadine Krockow

Soft tissue integration in the transmucosal zone of dental abutments supports the peri-implant tissues, improves esthetics, ensures soft tissue seal against microorganisms, and preserves crestal bone level. The aim of this literature review was to define the most favorable surface topography and macrodesign of the transmucosal zone of abutments to achieve optimal soft tissue seal. An electronic...

Journal: :The International journal of oral & maxillofacial implants 2012
Seong Kyun Kim Jai Young Koak Seong Joo Heo Thomas D Taylor Sook Ryoo Su Young Lee

PURPOSE The purpose of this study was to observe and compare any loosening of screws attaching several interchangeable abutments to internally connected implants after cyclic loading. MATERIALS AND METHODS Four different abutment groups mated with Straumann single-stage transmucosal implants (n = 7 each group) were assessed: Straumann solid abutment, Restore COC abutment, Neoplant solid abutm...

Journal: :International Journal of Oral & Maxillofacial Implants 2021

Serdar Yenigun, DDS, PhD/Pinar Ercal, PhD/Elif Ozden-Yenigun, PhD/Ahmet Bulent Katiboglu, PhD: Purpose: The aim of this study was to determine the effect solid (one-piece) and two-piece abutments on stress profile narrow implants with marginal bone loss. Materials Methods: Solid were connected a conical internal octagon–connection implant (3.3 mm in diameter, 10 length) restored single crown. ...

2015
Marc van Hoof Stina Wigren Hans Duimel Paul H. M. Savelkoul Mark Flynn Robert Jan Stokroos

INTRODUCTION Percutaneous implants, such as bone conduction hearing implants, suffer from complications that include inflammation of the surrounding skin. A sealed skin-abutment interface can prevent the ingress of bacteria, which should reduce the occurrence of peri-abutment dermatitis. It was hypothesized that a hydroxyapatite (HA)-coated abutment in conjunction with soft tissue preservation ...

Journal: :The Journal of laryngology and otology 2013
M D Darley A A Mikulec

BACKGROUND Most of the literature regarding osseointegrated implantation for hearing rehabilitation focuses on the 5.5 mm abutment. This study aimed to add to the data available on the survival of the 8.5 mm abutment, and to describe its utility in obese patients. OBJECTIVE To review the outcomes of patients who received a bone-anchored hearing aid implant, and create a model comparing the me...

نمودار تعداد نتایج جستجو در هر سال

با کلیک روی نمودار نتایج را به سال انتشار فیلتر کنید