نتایج جستجو برای: pmu

تعداد نتایج: 744  

2013
Yuancheng Li Bei Wang Yiliang Wang Xianji Wang

Dynamic State Estimation (DSE) techniques have the ability to foresee potential contingencies and security risks. Any improvement in its ability to estimate would definitely go a long way in reducing the security risks in the modern power system. One important factor affecting the quality of estimation is the measurement accuracy. Phasor Measurement Unit (PMU) has revolutionized the way state e...

Journal: :Investigative ophthalmology & visual science 2015
Kathryn L Pepple Lauren Rotkis Jennifer Van Grol Leslie Wilson Angela Sandt Deborah L Lam Eric Carlson Russell N Van Gelder

PURPOSE The purpose of this study was to compare the histologic features and cytokine profiles of experimental autoimmune uveitis (EAU) and a primed mycobacterial uveitis (PMU) model in rats. METHODS In Lewis rats, EAU was induced by immunization with interphotoreceptor binding protein peptide, and PMU was induced by immunization with a killed mycobacterial extract followed by intravitreal in...

2016
Paolo ROMANO

The increasing penetration of Distributed Energy Resources (DERs) at the low andmediumvoltage levels is determining major changes in the operational procedures of distribution networks (DNs) that are evolving from passive to active power grids. Such evolution is causing non-negligible problems to DN operators (DNOs) and calls for advanced monitoring infrastructures composed by distributed sensi...

Journal: :CoRR 2013
Kyatsandra G. Nagananda

The goal of this paper is to study the impact of the dynamic nature of bus voltage magnitudes and phase angles, which constitute the state of the power system, on the phasor measurement unit (PMU) placement problem. To facilitate this study, the placement problem is addressed from the perspective of the electrical structure which, unlike existing work on PMU placement, accounts for the sensitiv...

2015
Mohammad Yasinzadeh Mahdi Akhbari

Phasor measurement unit (PMU) GPS receiver spoofing has been addressed in the recent literatures. Having spoofed GPS signals, the spoofer can inject bad data into power system control center and consequently the protection system will face serious problems. The existing anti spoofing techniques are all based on GPS signal analysis and are just able to detect spoofing. However, as PMUs are place...

2016
L. Shalalfeh P. Bogdan E. Jonckheere

In [4], we have studied the statistical properties and mono-fractality of the power system time series, voltage magnitude (V), frequency (f), and phase angle (θ). The power system data was measured using three Phasor Measurement Units (PMUs) installed at Baylor University, Harris Substation, McDonald Observatory in the Texas Synchrophasor Network [1]. Our analysis of several data sets has shown...

پایان نامه :وزارت علوم، تحقیقات و فناوری - دانشگاه کاشان - دانشکده مهندسی 1390

فناوری اندازه گیری سنکرون کمیات فازوری شبکه های قدرت فناوری نسبتاً جدیدی است و به همین دلیل گروه های تحقیقاتی زیادی در سراسر دنیا درباره کاربردهای آن فعالیت میکنند. با استفاده از واحد اندازه گیری فازوری تخمین و نمایش دقیق حالت سیستم قدرت در فواصل زمانی معین امکان-پذیر می شود که بدین ترتیب می توان پدیده های دینامیکی سیستم را از یک محل مرکزی مشاهده و عملیات کنترلی مناسب را اعمال نمود. در این پایان...

2012
JIANGMENG ZHANG Alejandro D. Domínguez-García Alejandro D. Domínguez Peter W. Sauer

This thesis proposes a method to analyze power system stability by utilizing PMU measurements. As the current power system is operated close to its limits, stability is of high concern for both operators and customers. The implementation of phasor measurement units across the power system allows for accurate and fast stability monitoring and analysis. To address the application of PMU measureme...

2016
Teklemariam Tsegay Tesfay Ola Svensson Jean-Yves Le Boudec

Phasor measurement units (PMUs) deployed to monitor the state of an electrical grid need to be patched from time to time to prevent attacks that exploit vulnerabilities in the software. Applying some of these patches requires a PMU reboot, which takes the PMU offline for some time. If the PMU placement provides enough redundancy, it is possible to patch a set of PMUs at a time while maintaining...

نمودار تعداد نتایج جستجو در هر سال

با کلیک روی نمودار نتایج را به سال انتشار فیلتر کنید