In response to the localized corrosion generated by underground casing, which seriously affects safe operation of salt cavern compressed air storage, we used commercial finite element software, ANSYS, propose a partial model applicable casings with pitting and strip corrosion. The results show that depth casing is closely related fracture collapse pressure. As increases, its effect on pressure ...