نتایج جستجو برای: selective separation

تعداد نتایج: 318588  

Integrally-skinned asymmetric Polyetherimide/Poly (vinyl alcohol) (PEI/PVA) hollow fber membranes for pervaporation dehydration were fabricated by non-solvent induced phase inversion. PVA inside the PEI matrix could be crosslinked to provide membrane performance stability during long term operation. The effects of different PEI/PVA blend ratio, external coagulant type and...

Journal: :the iranian journal of pharmaceutical research 0
tayebeh ghari 1- department of pharmaceutics, school of pharmacy, shahid beheshti university of medical sciences, tehran, iran. 2- students research committee, school of pharmacy, shahid beheshti university of medical sciences, tehran, iran. farzad kobarfard department of pharmaceutical chemistry, school of pharmacy, shahid beheshti university of medical sciences, tehran, iran. seyed alireza mortazavi department of pharmaceutics, school of pharmacy, shahid beheshti university of medical sciences, tehran, iran.

the present study was designed to develop a simple, validated liquid chromatographic method for the analysis of azithromycin in bulk and pharmaceutical dosage forms using ultraviolet detector. the best stationary phase was determined as c18 column, 5 µm, 250 mm × 4.6 mm. mobile phase was optimized to obtain a fast and selective separation of the drug. flow rate was 1.5 ml/min, wavelength was se...

The present study was designed to develop a simple, validated liquid chromatographic method for the analysis of azithromycin in bulk and pharmaceutical dosage forms using ultraviolet detector. The best stationary phase was determined as C18 column, 5 µm, 250 mm × 4.6 mm. Mobile phase was optimized to obtain a fast and selective separation of the drug. Flow rate was 1.5 mL/min, Wavelength was se...

The present study was designed to develop a simple, validated liquid chromatographic method for the analysis of azithromycin in bulk and pharmaceutical dosage forms using ultraviolet detector. The best stationary phase was determined as C18 column, 5 µm, 250 mm × 4.6 mm. Mobile phase was optimized to obtain a fast and selective separation of the drug. Flow rate was 1.5 mL/min, Wavelength was se...

Journal: :journal of nanostructures 2014
a. akbari a. yunessnia lehi z. ghaedamini haruni

several novel composite membranes were prepared to separate and recycle amoxicillin from pharmaceutical wastewater via nanofiltration process. the synthesis of these membranes included three stages: 1- preparation of polysulfone ultrafiltration membranes as a support via phase separation process, 2- modification of its surface by interfacial polymerization as a selective layer (polyamide), and ...

Journal: :Angewandte Chemie 2023

Receptors. In their Communication (e202216011), Jan J. Weigand et al. report the selective separation of lithium, magnesium, and calcium using 4-phosphoryl pyrazolones as pH-regulated receptors.

2015
Ziyin Fan Melissa Köhn Serrano Andreas Schaper Seema Agarwal Andreas Greiner

Polymer cages prepared by etching of gold nanoparticles from polymer templates by the "grafting around" method are designed for selective separation of metal nanoparticles. The separation process is demonstrated as a fast biphasic ligand exchange reaction. The high separation efficiency and size selectivity of the polymer cage is verified by comparison with the linear block copolymer.

نمودار تعداد نتایج جستجو در هر سال

با کلیک روی نمودار نتایج را به سال انتشار فیلتر کنید