نتایج جستجو برای: shaft angle
تعداد نتایج: 140630 فیلتر نتایج به سال:
BACKGROUND Recent studies suggest that even a mild slip of the femoral capital epiphysis may lead to later degenerative changes when undiagnosed. However, little is written on the accuracy of radiographic measurements used to diagnose a slip at skeletal maturity. PURPOSE To assess the accuracy of radiographic measurements commonly used for assessment of previously slipped capital femoral epip...
Measurements were made of the femoral shaft/neck angle (CCD angle) in 106 human foetuses, aged from 16 to 38 hbd, using a "FEM-GEO_03" computer program. The values of the CCD angle in the group under examination were: mean = 140.48 degrees, SD = 6.95 degrees, max = 157.90 degrees, min = 113.93 degrees. No significant differences were found in CCD angle size between male and female foetuses or b...
OBJECTIVE To know the effectiveness of a custom molded fitting chair between pre- and post-chair status through comparison of musculoskeletal indices in severely disabled children. METHODS We researched 34 severely disabled patients who had used a custom molded fitting chair continuously for more than a year. There were 27 cerebral palsy patients and 7 patients with other kinds of diseases th...
PURPOSE To assess the radiographic features of 36 hips with hereditary multiple exostoses (HME). METHODS Hip parameters of 12 males and 6 females (36 hips) aged 2 to 28 years with HME were assessed using anteroposterior radiographs. The recorded features included the sites of osteochondromas, the femoral head/neck ratio, the Reimer's migration percentage, Sharp's acetabular angle, the centre ...
A resolver is a position sensor or transducer that measures the instantaneous angular position of the rotating shaft to which it is attached. Resolver produces two amplitude modulated signals; SIN and COS as output signals. These two signals need to be demodulated and converted to digital signals before they can be used for control. There are several techniques available in the literature to me...
Reverse shoulder arthroplasty, introduced by Grammont et al. [1] in 1987, is commonly associated with scapular notching, [2] an impingement of the humeral cup against the scapula’s inferior border. Although the clinical significance of notching has been debated, 2 studies reported less successful clinical outcomes in its presence [2,3]. A laboratory study showed that a varus humeral neck-shaft ...
Trochanteric growth disturbance after upper femoral osteotomy for congenital dislocation of the hip.
We reviewed 14 patients (16 hips) treated by open reduction and upper femoral derotation osteotomy for congenital dislocation of the hip. Nine patients with 11 treated hips had growth deformities of the proximal femur; in all of them the top screw of the fixation plate lay within the cartilaginous precursor of the greater trochanter. In the five control hips the top screw was more distal. In th...
BACKGROUND Research into the optimal treatment of fibrous dysplasia has been limited by the lack of an established classification system for the disease. The purposes of this study were to develop a radiographic classification for fibrous dysplasia of the proximal femur and to test this classification's intra- and interobserver reliability as well as the effectiveness of our treatments. METHO...
Magnetic angle sensors detect the angular position of a permanent magnet attached to a rotating shaft. The magnet is polarized diametrically to the rotation axis. No soft magnetic flux guides are present. The semiconductor die is placed on and orthogonal to the rotation axis. There are two kinds of systems: (i) perpendicular systems detect the field components perpendicular to the rotation axis...
نمودار تعداد نتایج جستجو در هر سال
با کلیک روی نمودار نتایج را به سال انتشار فیلتر کنید