نتایج جستجو برای: specular
تعداد نتایج: 3089 فیلتر نتایج به سال:
AIMS To compare central corneal thickness measurements of three pachymetry devices in eyes after laser in situ keratomileusis (LASIK). METHODS Central corneal thickness was measured in 203 eyes after myopic LASIK. Orbscan II scanning slit topography (Bausch & Lomb), SP-2000P non-contact specular microscopy (Topcon), and ultrasonic pachymetry (Tomey) were used in this sequence. RESULTS Three...
In projection-based augmented reality, specular reflection may distract the users. This paper demonstrates that the specular reflection can be eliminated by redundantly illuminating the projection surface using multiple overlapping projectors mounted at different locations. Our initial system using two projectors is presented. The system automatically determines the pixels which include specula...
In Photometric stereo, the existence of specularities hampers to recover the normal map. To deal with this common reflective phenomenon, we introduce a novel representation for specular reflection with a set of specular basis functions with different roughness values. This representation is suitable for any intensively or weakly specular object, and is introduced into the photometric stereo alg...
Cationorm® (CN) cationic nanoemulsion was demonstrated to enhance tear film (TF) stability in vivo possibly via effects on tear film lipid layer (TFLL). Therefore the interactions of CN with human meibum (MGS) and TFLL in vitro and in vivo deserve special study. MGS and CN were spread at the air/water interface of a Langmuir surface balance to ensure a range of MGS/CN oil phase ratios: 20/1, 10...
There is a growing trend in machine color constancy research to use only image chromaticity information, ignoring the magnitude of the image pixels. This is natural because the main purpose is often to estimate only the chromaticity of the illuminant. However, the magnitudes of the image pixels also carry information about the chromaticity of the illuminant. One such source of information is th...
BACKGROUND The aim was to compare the repeatability, reproducibility and inherent precision of ultrasound pachymetry (USP), noncontact specular microscopy (SP-2000P) and the Confoscan 4 confocal microscope (z-ring CS4) in measuring endothelial cell density (ECD), coefficient of variation of cell size (CV), and central corneal thickness (CCT) in normal eyes. METHODS In this prospective study, ...
One of the problems that hinders conventional methods for shape-from-shading is the presence of local specularities which may be misidenti.ed as high curvature surface features. In this paper we address the problem of estimating the proportions of Lambertian and specular re1ection components in order to improve the quality of surface normal information recoverable using shape-from-shading. The ...
نمودار تعداد نتایج جستجو در هر سال
با کلیک روی نمودار نتایج را به سال انتشار فیلتر کنید