نتایج جستجو برای: volumetric modulated arc radiotherapy

تعداد نتایج: 173599  

2016
Paul Kinsella Laura Shields Patrick McCavana Brendan McClean Brian Langan

Multileaf collimators (MLCs) need to be characterized accurately in treatment planning systems to facilitate accurate intensity-modulated radiation therapy (IMRT) and volumetric-modulated arc therapy (VMAT). The aim of this study was to examine the use of MapCHECK 2 and ArcCHECK diode arrays for optimizing MLC parameters in Monaco X-ray voxel Monte Carlo (XVMC) dose calculation algorithm. A ser...

2017
Jung-in Kim Chang Heon Choi Hong-Gyun Wu Jin Ho Kim Kyubo Kim Jong Min Park

The aim of this work was to investigate correlations between 2D and quasi-3D gamma passing rates. A total of 20 patients (10 prostate cases and 10 head and neck cases, H&N) were retrospectively selected. For each patient, both intensity-modulated radiation therapy (IMRT) and volumetric modulated arc therapy (VMAT) plans were generated. For each plan, 2D gamma evaluation with radiochromic films ...

2011
Alessandro Clivio Giorgia Nicolini Eugenio Vanetti Antonella Fogliata Luca Cozzi

BACKGROUND A new-generation low-energy linear accelerator (UNIQUE) was introduced in the clinical arena during 2009 by Varian Medical Systems. The world's first UNIQUE was installed at Oncology Institute of Southern Switzerland and put into clinical operation in June 2010. The aim of the present contribution was to report experience about its commissioning and first year results from clinical o...

Journal: :Physics in medicine and biology 2009
Grace Tang Matthew A Earl Cedric X Yu

Single-arc intensity-modulated arc therapy (IMAT) has gained worldwide interest in both research and clinical implementation due to its superior plan quality and delivery efficiency. Single-arc IMAT techniques such as the Varian RapidArc deliver conformal dose distributions to the target in one single gantry rotation, resulting in a delivery time in the order of 2 min. The segments in these tec...

2005
Piotr Zygmanski Fred Hacker Scott Friesen Robin Rodenbush Hsiao‐Ming Lu Lee Chin

The analysis of dynamic multileaf collimator (MLC) positions for the delivered intensity-modulated radiotherapy (IMRT) plans is crucial in that it may capture dose delivery problems otherwise difficult to observe and quantify in the conventional dosimetric measurements with film or with an ionization chamber. In some IMRT systems, delivery of IMRT fields starts with a maximum MLC opening (rough...

2010
Taoran Li Xiaofeng Zhu Danthai Thongphiew W. Robert Lee Zeljko Vujaskovic Qiuwen Wu Fang-Fang Yin Q. Jackie Wu

The purpose of this paper is to evaluate the feasibility and clinical dosimetric benefit of an on-line, that is, with the patient in the treatment position, Adaptive Radiation Therapy (ART) system for prostate cancer treatment based on daily cone-beam CT imaging and fast volumetric reoptimization of treatment plans. A fast intensity-modulated radiotherapy (IMRT) plan reoptimization algorithm is...

2011
Jidi Sun Theam Yong Chew Juergen Meyer

BACKGROUND 2-step intensity modulated arc therapy (IMAT) is a simplified IMAT technique which delivers the treatment over typically two continuous gantry rotations. The aim of this work was to implement the technique into a computerized treatment planning system and to develop an approach to optimize the segment weights and widths. METHODS 2-step IMAT was implemented into the Prism treatment ...

2004
Carlos Daniel Venencia Pelayo Besa

The objective of this paper is to present our experience in the commissioning and quality assurance (QA) for intensity modulated radiotherapy (IMRT) using dynamic multileaf collimator (dMLC), sliding window technique. Using Varian equipment solution, the connectivity and operation between all IMRT chain components was checked. Then the following test were done: stability of leaf positioning and...

2010
Youling Gong Shichao Wang Lin Zhou Yongmei Liu Yong Xu You Lu Sen Bai Yuchuan Fu Qingfeng Xu Qingfeng Jiang

PURPOSE To study the impacts of multileaf collimators (MLC) width [standard MLC width of 10 mm (sMLC) and micro-MLC width of 4 mm (mMLC)] in the intensity-modulated radiotherapy (IMRT) planning for the upper thoracic esophageal cancer (UTEC). METHODS AND MATERIALS 10 patients with UTEC were retrospectively planned with the sMLC and the mMLC. The monitor unites (MUs) and dose volume histogram-...

Journal: :Acta oncologica 2013
Gwendolyn Griffioen Max Dahele Marloes Jeulink Suresh Senan Ben Slotman Wilko F Verbakel

نمودار تعداد نتایج جستجو در هر سال

با کلیک روی نمودار نتایج را به سال انتشار فیلتر کنید